UK
• After installation, always carefully check proper functioning of the system and the devices used.
• This instruction manual addresses persons qualified for installation of "live equipment". Therefore, good technical
knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed. Check the intended end use and take
all the necessary safety precautions.
• Use of the product for purposes different from the intended use has not been tested by the manufacturer, therefore
any work is carried out on full responsibility of the installer.

WARNINGS FOR THE USER

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. Any
repairs must be carried out by specialised personnel using original and certified materials.
The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or lacking
experience and knowledge, unless appropriately instructed.
Do not access the board for adjustments and/or maintenance.
CAUTION: IMPORTANT SAFETY INSTRUCTIONS
It is important to follow these instructions in order to safeguard persons.
Keep this instruction booklet.
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
M1
M2
M3
M4
NOTE
If using detection devices already connected to gate opening control units, make sure that you connect the commons
to each other.
Signal
1
N
2
L
3
24 Vac
4
24 Vac
OPENING LIMIT
5
SWITCH
OPENING LIMIT
6
SWITCH
7
*IN_1
8
*IN_1
9
IN_2
10
IN_2
11
*C_1
12
*R_1
13
*V_1
14
C_2
15
R_2
16
V_2
Description
230 Vac power supply Neutral input
230 Vac power supply Line input
External light power supply output
External light power supply output
Opening limit switch input
Opening limit switch common
Detection device 1 input
Detection device 1 common. See Note.
Detection device 2 input.
Detection device 2 common. See Note.
Lights 1 common
Red light 1
Green light 1
Lights 2 common
Red light 2
Green light 2