Installation tool/ Installation
sequence
Dimensions
Technical Data
Note
Points out information to the affected
personnel, whose content is important
and must be taken into consideration.
Water connection
Warm water
Water connection
Cold water
Electrician
The installation and testing work must
be performed by a skilled electrician
in observance of VDE 0100 part 701
and IEC 60364-7-701.
Water on / off
Installation sequence
Silicone (free from acetic
acid!)
Plug outlets
Plug the unused outlet.
Pipe decline
Install water pipes for body showers
with a gradient.
Electricity on / off
Empty pipe EN20
PE
PE
Potential equalisation
GB
N N
neutral conductor
L L
conductor
FI FI
FI protective switch
light switch
transformer
Illuminant
Connecteur
Amplifier for speaker
X X
Middle of shower stall
Wall construction
In this area is a reinforcement
necessary.
Electrical connection
Preinstall electrcal power 230 V/N/PE/50 Hz
(length: 0.3 m)
The current version of the applicable regulations
from VDE, local authorities and utility companies
must be observed for electric installation work.
Residual current protection system
The system must be protected via a leakage
current protective device (RCD/ FI) with a measu-
rement difference current of ≤ 30 mA.
Arrangement of the modules
Adjust the module arrangement to the local condi-
tions (Installation examples see pages 6...11.)
Fastening material
Only suitable fastening material may be used!
The enclosed screws and plugs are only suitable
for concrete.
Flush piping system
To complete the installation flush out both hot and
cold water supply.
Sequence power
The performance of the waste must be of sufficient
size.
non return valve
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Connections
Rate of flow by 0,3 MPa:
10750180 1 Consumer
10750180 2 Consumer
10650180
10971180
28486180
max. 1,0 MPa
0,15 - 0,6 MPa
1,6 MPa
max. 80° C
65° C
G ¾"
44 l/min
55 l/min
25 l/min
55 l/min
50 l/min
5