6. FIRING PARAMETERS

Pre-drying Temperature: 0 to 1000°C
Once the furnace has completed a cycle, the temperature drops to 300°C. After placing the
porcelain on the base, you then initiate the next cycle. At that point, the temperature rises from
300°C to the value set for the "pre-dry temperature". The platform will only begin to rise once the
"pre-drying" temperature has been reached.
Platform rise time: 0 to 30 min
The platform rise time is divided into 6 stages.
The platform will only begin rising once the pre-drying temperature has been reached.
That temperature will be maintained as long as the platform continues to rise.
Internal pre-drying: 0 to 30 min
While the platform is closed, the temperature is maintained at the "pre-dry temperature" for a
period programmable from 0 to 30 minutes.
The temperature will only begin to rise at the end of that time.
Vacuum start: 0 to 1000°C
Use this function to create a vacuum in the heating chamber at a different temperature from the
introduction temperature.
For a cycle without vacuum, program:
- Vacuum start: 0
- Vacuum level: 0
Vacuum stop: 0 to 1200°C
For vacuum firing, use this function to either cancel the cycle or maintain it starting at a defined
temperature.
Vacuum level: 0 to 99%
The programming unit on the ARTIS NEO furnace has an electronic vacuum sensor. As it is more
accurate and reliable than a conventional pressure gage, the vacuum level can be adjusted to
within ± 3% of the programmed value. Unit conversion: see chapter 13.
NOTE: The vacuum pump UGIN DENTAIRE has a 95% vacuum level capacity
Vacuum hold time: 0 to 60 min
Starting at the vacuum stop temperature, you can prolong the vacuum time by 0 to 60 minutes.
UGIN DENTAIRE
- Vacuum stop: 0
- Hold: 0
ARTIS NEO