Note: Press "8" then "ENTER" to restore the factory settings for user
controls and channel memories (this will also turn set off and then on
to exit the service mode).
2-9-2. MEMORY WRITE CONFIRMATION
METHOD
1. After adjustment, remove the plug from the AC outlet, and then
replace the plug in the AC outlet again.
2. Turn the power switch ON and enter the Service Mode.
3. Cycle through the adjusted items again and confi rm that the
adjustments were saved.
2-9-3. ADJUSTING BUTTONS AND
INDICATOR
Note: When the PJE mode (which displays an internally generated
signal) is activated, several buttons on the remote commander will have
different functions than the ones listed above. Therefore, when in the PJE
mode, refer to section 2-10 for button functions.
MUTING
Category up
Adjustment
item up
Adjustment
item down
TV Power ON
Display
Data up
Data down
Category down
ENTER
RM-Y906
— 17 —
KP-43T85T / 53SV85T / 61SV85T