Transport And Storage; Unpacking - Daikin MONTREAL XL Instrucciones De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6 | Transport and storage

Error code
Overtemperature on F4
Undertemperature alarm
Temperature logger alarm
Electronics fault
Overtemperature electronics
Compressor fault
Compressor fault due to E75
Voltage outside tolerance
Frequency outside tolerance
No communication with display
Electronics in test mode
Acknowledge alarm
Press
Deactivate key lock
multaneously for 5 seconds.
(Access to level 1)
Level 1 is activated.
The interior temperature and
Error code and Ac-
the symbol
knowledge acoustic
display.
alarm
(appliance-specific)
The symbol
until the error has been recti-
fied.
6
Transport and storage
a) Check the appliance for transport damage after
delivery.
b) In the event of damage to the appliance, contact
the maintenance service immediately [see } Chap-
ter 11.3.2].
WARNING
Damage to the refrigerant circuit.
Flammable refrigerant can escape and cause
an explosive gas/air mixture.
§ Do not expose the appliance to tempera-
tures higher than 70°C (158°F) during
transport and storage.
§ Ensure good ventilation.
§ Observe safety notices and warnings for
appliances with flammable refrigerants
[see } Chapter 2.5.2].
§ In the event of damage to the appliance,
contact the maintenance service immedi-
ately [see } Chapter 11.3.2].
Transport of the units with industrial
trucks.
40 / 104
Meaning
and
si-
appears on the display.
Briefly press.
appear on the
is illuminated
AHT Cooling Systems GmbH | en-US
Risk of injury to persons in the event of a colli-
sion.
§ Observe transport routes for industrial
trucks.
§ Secure transported goods.
§ Only trained personnel may operate in-
dustrial trucks.
§ Observe the stacking height specifications
on the packaging.
NOTICE
Material damage caused by transport and
storage.
§ Transport and store the unit only in a type-based
stable operating position (horizontal alignment).
§ Observe the stacking height specifications on the
packaging.
§ If the appliance was tilted during transport, wait a
minimum of two hours before start-up.
§ On delivery, ensure full accessibility to the installa-
tion point (observe clearance heights, clearance
widths, installation space height, sufficient turning
radii).
§ Do not store the appliance outdoors.
7

Unpacking

Responsibility
– Operating company
a) Check the appliance for damage before and during
unpacking.
b) In the event of damage to the appliance, contact
the maintenance service immediately [see } Chap-
ter 11.3.2].
WARNING
Disposal of packaging material and
films.
Danger of suffocation.
§ Keep packaging material and film away
from children.
§ Do not allow children to play with packag-
ing material or film.
Damage to the refrigerant circuit.
Flammable refrigerant can escape and cause
an explosive gas/air mixture. Risk of fire.
§ Ensure good ventilation.
§ Observe safety notices and warnings for
appliances with flammable refrigerants
[see } Chapter 2.5.2].
§ In the event of damage to the appliance,
contact the maintenance service immedi-
ately [see } Chapter 11.3.2].
440195_1_0521
Tabla de contenido
loading

Este manual también es adecuado para:

Montreal xl pushMontreal slimMontreal slim push

Tabla de contenido