Customer Service; Factory Default Reset (Fdr); Fcc Statement - Schlage LE Instrucciones De Instalación

Tabla de contenido
14
Continue to User Guide.
Your lock is now completely installed.

Customer Service

1-877-671-7011

Factory Default Reset (FDR)

A Factory Default Reset (FDR) will return the LE-series lock
settings to the original settings as shipped from the factory.
Removes configurations, databases, and requires the lock
to be re-captured. A FDR will not remove the lock from your
ENGAGE account.
A
Press and hold the FDR button for five seconds.
The LED will blink green two times and beep two times.
B
Turn the inside lever three times within 20 seconds.
LED will blink red and lock will beep with each turn.
C
Reinstall battery cover, then use the app to capture
your lock.
Turn the inside lever. The LE will communicate on BLE
looking for your mobile device for two minutes after each
lever turn in FDR mode.
If you have used this LE in Construction Access Mode, you
must complete a FDR before it will communicate on BLE.
Access online interactive
instructions, user guide,
warranty, and reference
information.
alle.co/LE
www.allegion.com/us

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communication. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
FCC Radiation Exposure Statement
To comply with FCC/IC RF exposure requirements for mobile transmitting devices, this
transmitter should only be used or installed at locations where there is at least 20 cm
separation distance between the antenna and all persons.
Industry Canada Statement
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its
gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not
more than that permitted for successful communication.
Industrie Canada Déclaration
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé
pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son
gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Industry Canada Radiation Exposure Statement
This Device complies with Industry Canada License-exempt RSS standard(s). Operation
is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Industrie Canada l'exposition aux radiations
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
UL Statements
• LEB models use Bluetooth credentials.
• Outside lever is normally locked. Inside lever always allows egress.
• The system shall not be installed in the fail-secure mode unless permitted
by the local authority having jurisdiction and shall not interfere with the
operation of Listed panic hardware.
• Unit shall not interfere with the operation of Panic Hardware.
• Wireless communications, Wi-Fi, Bluetooth, Door Position, and Request to
Exit switch features are not part of UL Listed product.
• Tested to compliance with UL 294 7th Edition.
• Tested to compliance with CAN/ULC-S319-05, Class I.
• Access Control Performance Levels
Destructive Attack
Line Security
IV
• Wiring methods shall be in accordance with the National Electrical Code
(ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety
Standard for Electrical Installations, local code, and the authorities having
jurisdiction.
• This product is not intended for outside wiring as covered by Article 800 in
the National Electrical Code, NFPA 70.
Endurance
Standby Power
I
IV
P518-027 Rev. 11/19-c
I
© Allegion 2019
Printed in U.S.A.
Tabla de contenido
loading

Este manual también es adecuado para:

Leb

Tabla de contenido