Initial Operation - HIKOKI GM 13Y Instrucciones De Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42

Initial Operation

Before plugging in the machine, check that the
rated mains voltage and mains frequency, as
specified on the rating label, match your power
supply.
Australia: Always use a residual current device
(RCD) protected supply with a rated residual
current of 30 mA or less.
1
Fitting of bar auxiliary handle
Always work with the bar auxiliary handle (1)
attached! Fit the bar auxiliary handle as shown
(Fig. 1).
- Fit locking discs (3) to the left and right of the gear
housing.
- Fit the bar auxiliary handle (1) at the gear housing.
- Insert the thumb screws (2) left and right into the
bar auxiliary handle (1) and turn gently.
- Adjust the bar auxiliary handle (1) to the required
angle.
- Firmly tighten the thumb screws (2) to the left and
right manually.
2
Dust extraction
Always use a suitable dust extraction system:
Connect an L-class and over vacuum cleaner
to the extractor connection piece (12).
For optimal dust extraction, use the connecting
sleeve.
Attaching the Accessory
Disconnect the mains plug before changing
any accessories. The machine must be
switched off and the spindle must be at a standstill.
1
Locking the spindle (Fig. 2)
Press in the spindle locking knob (11) only
when the spindle is stationary!
- Press in the spindle locking button (11) and turn
the spindle (9) by hand until you feel the spindle
locking button engage.
2
Fitting/removing the diamond cup wheel
(Fig. 2)
To fit:
- Fit the support flange (8) on the spindle. (9) The
flange should not turn on the spindle when prop-
erly attached.
- Lay the diamond cup wheel (7) on the support
flange (8) so that it lies flat along the support
flange.
- The two sides of the clamping nut (6) are different.
Screw the clamping nut onto the spindle so that
the band of the clamping nut (6) is facing upward.
- Lock the spindle. Turn the clamping nut (6) clock-
wise using the 2-hole spanner (5) to secure.
To remove:
- Lock the spindle. Turn the clamping nut (6) anti-
clockwise using the 2-hole spanner (5) to
unscrew.
Use
1
Working close to walls (Fig. 3)
To open and close the segment: switch off the
machine and pull the mains plug. The acces-
sory must be stationary.
Only raise the segment (13) when working
close to walls. Otherwise, the segment must
be lowered.
The open area of the safety guard must face the
direction of the wall.
2
Setting the speed (Fig. 3)
Set the optimum speed on the setting wheel (18),
depending on the application.
A wheel setting of between 4 and 6 is suitable for
most applications.
3
Switching On and Off
Always guide the machine with both hands.
Switch on first, then guide the accessory
towards the workpiece.
The machine must not be allowed to draw in
additional dust and shavings. When switching
the machine on and off, keep it away from dust
deposits. After switching off the machine, only set it
down when the motor has come to a standstill.
Avoid inadvertent starts: always switch the
tool off when the plug is removed from the
mains socket or if there has been a power cut.
In continuous operation, the machine
continues running if it is forced out of your
hands. Therefore, always hold the machine with
both hands using the handles provided, stand in a
safe position and concentrate on the work.
Torque activation
I
Switching on: Slide the trigger switch (16)
forwards and then push the trigger switch
(16) upwards.
Switching off: Release the trigger switch (16).
English
16
0
7
Tabla de contenido
loading

Tabla de contenido