Safety Device; Pressure Reducing Valve; Positioning The Unit - Energie MONOBLOC 100esm Manual Tecnico

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MONOBLOC 100L

4.1.5. Safety Device*

The safety device allows the system to be protected against anomaly situations: cold water supply, hot
water flowing back, em tying the storage water heater and high pressure. The valve is calibrated to acti-
vate at 0.7 Mpa.
In order to drain the water in the storage water heater, you should close the supply valve and open the
discharge valve.
The safety valve discharge pipe must be open into the atmosphere, because the va ve may drip water or
even discharge water.

4.1.6 Pressure Reducing Valve*

The pressure reducing valve must always be installed upstream from the safety device, and ready to acti-
vate in situations when the pressure in the circuit exceeds 3 bar (0,3MPa). This valve comes with a pressure
gauge.
*Components not supplied by the manufacturer, the installation is the responsibility of the installer

4.2. Positioning The Unit

Before starting the equipment assembly check out the wall's carrying capacity and
what kind of material is it made, considering the equipment's weight when loaded
with water.
WARNING
When placing the equipment in its position, bear in mind possible future interventions. To avoid having
too much space around the equipment, the magnesium anode is found on the front side of the water
storage heater.
Make sure that there is at least the following free space around the equipment.
40