• Make sure all hydraulic couplings are watertight before connecting the equipment to the power
supply.
Maintenance of the equipment:
• Equipment maintenance should be carried out by customer service, except operations of general and
continuous cleaning which could/should be carried out by the user;
• Power supply to the equipment must be disconnected when doing maintenance operations;
• The supplier recommends at least one annual inspection to the equipment, by a qualified technician;
• Cleaning and maintenance must not be carried out by children unless they are under supervision.
High pressure and temperature:
• The principle for running this equipment is directly linked to high temperature and pressure; thus, the
processes that imply contact with the equipment must be thought out with caution to prevent the
risk of burns and projection of material.
Refrigerant Fluid:
• The cooling fluid employed in the whole process is R134a, CFC-free, non-inflammable and without
harmful effects for the ozone layer;
• However, according to the law, the fluid in this equipment cannot be released into the environment;
• Handling of the fluid in the equipment must be carried out by a qualified technician.
Information for the Client:
• The Installer must inform the client about the running of the equipment, its dangers, rights and duties
of the client.
2. SPECIFICATIONS
2.1. Dimensions
A
1275 mm
B
420 mm
C
855 mm
D
520 mm
MONOBLOC 100L
E
724 mm
F
450 mm
G
15 mm
H
115 mm