CLEARANCE
HOLE
8. Finish ceiling.
Cut an opening in finished ceiling material for housing collar.
SPRINGS
LAMP
BRACKET
9. Attach trim ring / baffle to housing.
Remove the cardboard protector from inside the housing collar.
Use a pencil to insert one end of each spring into the holes on the
lamp bracket. Center trim ring / baffle in ceiling opening.
10. Install bulb.
CAUTION - RISK OF FIRE: Use only R30, BR30, or PAR30
shaped, 16W compact fluorescent lamp with GU24 base
(supplied). Replacement bulbs can be ordered from
Broan if not available locally (see service parts list).
!
CAUTION: Twist bulb to install or remove.
FINISHED
CEILING
MATERIAL
HOUSING
COLLAR
TRIM RING / BAFFLE
SERVICE PARTS
1
2
3
4
9
15
8
11
12
KEY NO.
PART NO.
1
97014185
2
97016382
3
98003036
4
98005512
5
99524804
6
99524805
7
99080731
97020054
8
-------------
9
99420551
10
98010900
11
-------------
97018937
12
99524802
13
99525160
14
99271448
15
98010583
Order replacement parts by PART NO. - not by KEY NO.
* Lamp Bracket Assembly must be removed to service these
parts.
MODEL 744FLNT
Page 4
Lamp Bracket Assembly
must be removed to
service these parts.
5
6
10
13
14
DESCRIPTION
Damper / Duct Connector
Housing Assembly
Mounting Bracket (4 req.)
Wiring Adaptor Plate
Blower Wheel *
Motor Bracket / Venturi *
Motor *
Motor / Motor Bracket Assembly
(includes Key Nos. 6 & 7) *
Receptacle
Plastic Wire Clip
Lamp Bracket
Harness, GU24 Socket
Lamp Bracket Assembly
(includes Key Nos. 8 thru 11)
Trim Ring / Baffle with Springs
Baffle Springs (2 req.)
Fluorescent Lamp
Electrical Box Cover
99045497A
7