MODEL 770RNLTK
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from be-
ing switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not install in a bathtub or shower enclosure.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently protected.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS ONLY. Do
not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan housing assembly
included with this product. Do not mount the light fixture assembly to
a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
5. Please read specification label on product for further information and
requirements.
PLAN THE INSTALLATION
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
housing.
4-IN. ROUND
DUCT*
Seal duct
joints with
*Purchase
4-IN. ROUND
tape.
separately.
ELBOWS*
Ventilation Fan with Decorative Light
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
OR
WALL CAP*
(with built-in
damper)
Register this product at www.nutone.com/register. For Warranty Statement,
or to order Service Parts: go to www.broan.com and type the Model in the
"Model Search" field at the top of the page.
Broan, 926 W. State Street, Hartford, WI 53027 888-336-3948
TYPICAL INSTALLATIONS
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
HOUSING MOUNTED
TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*
Additional framing must be a 2x6 (minimum height).
INSTALL THE HOUSING
- PLEASE NOTE -
THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6
JOISTS. IF YOU HAVE A TRUSS OR "I"-JOIST INSTALLATION, MOUNT
THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MAN-
NER. (Additional framing must be a 2x6 (minimum height).
New Construction
1. Choose the location for your fan in the ceiling. For best possible
performance, use the shortest possible duct run and a minimum
number of elbows.
2. Position mounting brackets
against joist so that bottom
edge of housing will be flush
with finished ceiling.
Additional positioning
feature for 5/8", 1", &
1-1/4" thick ceiling material:
Holes in corners of housing
are labeled with various ceiling
material thicknesses. Position
housing so bottom edge of joist is visible through a matched
set of holes. The housing is now in the proper position for that
ceiling material thickness.
Additional positioning feature for 1/2" thick ceiling material:
Bend two tabs, on side of housing, 90
tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.
POWER CABLE
MOUNTING
TABS
2 x 4
CEILING
JOIST or
TRUSS
HOUSING
CEILING
MATERIAL
LIGHT SHADE
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*
SUSPENDED CEILINGS
Housing hung with wires -
3-point mount.
HOLES
TAB
1-1/4
1
5/8
BOTTOM EDGE OF JOIST
outward. Lift housing until
0
ADDITIONAL
*
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
PAN
GLASS
Tabla de contenido
loading

Resumen de contenidos para NuTone 770RNLTK

  • Página 1 Ventilation Fan with Decorative Light Register this product at www.nutone.com/register. For Warranty Statement, MODEL 770RNLTK or to order Service Parts: go to www.broan.com and type the Model in the READ AND SAVE THESE INSTRUCTIONS “Model Search” field at the top of the page.
  • Página 2: Connect The Wiring

    INSTALL THE DUCTWORK New Construction FLUSH 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks. NOTE: The duct connector has a counter-balanced damper flap. The flap will be “open” approx. 1” when duct connector is attached to hous- 4.
  • Página 3 6. Restore electrical power and check operation of the unit. Ventilateur Décoratif avec la lumière Enregistrez ce produit sur www.nutone.ca/register. Pour la déclaration de MODÈLE 770RNLTK garantie ou pour commander des pièces de rechange: allez sur www.broan.
  • Página 4: Planification De La Pose

    PLANIFICATION DE LA POSE INSTALLATIONS TYPES ISOLANT (Peut être placé sur le boîtier CAPUCHON de ventilateur et autour.) TOITE* (avec registre BOÎTIER DE intégré) VENTILATEUR CÂBLE ÉLECTRIQUE* Garder les conduits courtes. BOÎTIER FIXÉ DIRECTEMENT BOÎTIER FIXÉ AUX AUX SOLIVES DE FERMES DE 2X4 2x6 (ou plus) Les brides de montage exigent...
  • Página 5: Utilisation Et Entretien

    FIXATION DE LA PLAQUE DE PROTECTION Bâtisse déjà construite ET DU GLOBE DE VERRE COLORÉ 4. Placez le boîtier dans l’ouverture de sorte que 1. Repérez la plaque PLAQUE DE son arête inférieure affleure de protection sur le SUPPORT la surface finie du plafond. DE MOTEUR boîtier de ventilateur Clouez chaque bride à...
  • Página 6 Ventilador Decorativa con la luz Registre este producto en www.nutone.com/register. Para Declaración de MODELO 770RNLTK garantía, o para pedir piezas de servicio: vaya a www.broan.com y escriba el modelo en el campo “Model Search” en la parte superior de la página.
  • Página 7: Instalación Del Sistema De Conductos

    Construcción nueva 4. Coloque la cubierta en la abertura de manera que su borde inferior quede al ras del cielo raso terminado. Clave la cubierta en la vigueta a través del orificio en forma de cerradura, en ambos lados. Para asegurar un montaje sin ruido, coloque otro clavo en el orificio superior de cada aleta de montaje.
  • Página 8: Conexión Eléctrica

    CONEXIÓN ELÉCTRICA USO Y CUIDADO ADVERTENCIA: DESCONECTE LA CORRIENTE ELECTRICA Y BLOQUEE EL NEGRO ROJO RECEPTÁCULO BLANCO (LAMP.) BLANCO TIERRA TABLERO DE SERVICIO ANTES DE LIMPIAR OR REPARAR LA UNIDAD. (desnudo) AZUL RECEPTÁCULO CONTROL DOBLE NEGRO (VENT.) REEMPLAZO DEL FOCO (se vende por separado) CAJA DEL CONMUTADOR Quite la pantalla de vidrio.

Tabla de contenido