Exterior use or use outdoors, weather-resistant
Specification
When selecting cable for the AC installation, ensure to comply with local and national regulations.
Recommended minimum
cable requirements
Jacketed cable (rubber in-
sulation)
Outdoor use
Temperature range
Outdoors ⌀ max.
Table 2.2: AC Cable
Fuses
The main purpose of the fuse is to protect the installation against short circuits. It is recommended
to use a slow fuse, class C. When selecting the fuse for the AC installation, ensure to comply with
local and national regulations.
Specification
Fuse
Current
Voltage
Table 2.3: Recommended fuses
An automatic test of the inverter can be initialised by using the Inverter Autotest Software. Please
read the Autotest manual before initialising the software. Software and manual are available free
of charge, please contact your supplier for further information. The software is used in conjunction
with an RS485 to USB converter in order to communicate between inverter and PC. Such a con-
verter can be purchased at any retailer of computer equipment.
Note:
This is an international inverter. The inverter is approved and certified to run in 16 countries.
The inverter has not had country settings specified. It will not run before this has been done.
Check that all connections have the correct polarity and that cables are securely fastened. Turn
on the AC grid. The display will now prompt for "Language".
Illustration 2.13: Language
Illustration 2.14: Country
The inverter will start automatically if sufficient solar radiation is available. The start-up will take
a few minutes. During this period, the inverter will carry out a self-test.
ULX 1800o
ULX 3000o / 3600o
2
H05RN-F3G 2.5
H05RN-F3G 1.5 mm
≥500 [V]
-30 °C- +60 °C
-30 °C- +60 °C
10 mm
ULX 1800o
ULX 3000o / 3600o
16 A
16 A
240 V
240 V
Press '
es. Select language by pressing 'OK'. The dis-
play will now show "Country" in the language
chosen previously.
Press '
countries. Select the country in which the in-
verter is installed by pressing 'OK'. Confirm
selection by pressing 'OK'
The settings for the selected country has now
been activated, and the inverter is ready to
energise the AC grid.
L00410363-05_2q
2. Installation and Setup
ULX 5400o
H05RN-F3G 4.0 mm
2
mm
≥500 [V]
≥500 [V]
-30 °C- +60 °C
10 mm
10 mm
ULX 5400o
25 A
240 V
' to scroll down through the languag-
' to scroll down through the list of
2
2
13
Tabla de contenido
loading

Este manual también es adecuado para:

Ulx 1800oUlx 3000oUlx 3600oUlx 5400o

Tabla de contenido