General Specifications - Klein Tools CL2300 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ENGLISH
The Klein Tools CL2300 is a True RMS, auto-ranging clamp meter. It
measures AC / DC voltage, AC / DC current, resistance, capacitance,
frequency, duty cycle, and temperature. It can also test non-contact
voltage, diodes, and continuity.
Operating Altitude:
Humidity:
80% max
Operating Temperature:
Storage Temperature:
Accuracy Temperature:
Temperature Coeffi cient:
Dimensions:
11.9oz.
Weight:
Calibration:
CAT Rating:
± (% of reading + # of least signifi cant digits)
Accuracy:
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring
a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fi ngers away from
the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes
are connected.
• Use caution when working with voltages above 60V DC,
or 25V AC RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
~
AC Alternating Current
DC Direct Current
DC/AC Voltage or Current
Ground
AC Source
CL2300
Instruction Manual

GENERAL SPECIFICATIONS

2000 meters
0°C / 32°F to 45°C / 113°F
0°C / 32°F to 60°C / 140°F
18°C / 64°F to 28°C / 82°F
0.1*(specifi ed accuracy) / °C
7.65" x 2.56" x 1.375"
Accurate for one year
CAT IV 600V
WARNINGS
SYMBOLS
Warning or Caution
Dangerous levels
Double Insulated Class II
Safe for disconnect
from live conductors
Tabla de contenido
loading

Tabla de contenido