DITEC E1T Manual De Instalación página 15

Cuadro electrónico para automatismos 400 v trifásicos de 1 motor
Ocultar thumbs Ver también para E1T:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
7.
EXAMPLE OF PARALLEL AUTOMATIONS
A
B
It is possible to command two automations [A] and [B] side by
side, making the connections indicated in fig. 7.1.
To manage both automations with a single remote control insert
a BIXLR22 receiver.
Automatic closing is obtained by connecting the terminals 1-
2 and adjusting the TC trimmer in the same position in both
control panels.
If you use partial opening 1-20, adjust the RP trimmer in the
same position in both control panels.
Note: the opening and closing movements may not be syn-
chronised.
Attention: in the absence of safety edges SOFA1-SOFA2, con-
nect commands 1-6 and 1-8 to the SWT card.
Any PT3/PT4 membrane push-button panels connected to the
E1T control panel only open/close the automation to which they
are connected.
JR1=NO
JR2=CH1
JR1 JR2
0
6 8
41
6 8
1 2 3 4 5 6
DIP1=ON
A
15
GB
NO RADIO
0
6 8
41
6 8
1 2 3 4 5 6
DIP1=ON
B
Fig. 7.1
E1T - IP1897
Tabla de contenido
loading

Tabla de contenido