GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally
competent personnel only.
The installation, the power connections and the settings must
be completed in conformity with Good Working Methods and
with the regulations in force. Before installing the product, care-
fully read the instructions. Bad installation could be hazardous.
The packaging materials (plastic, polystyrene, etc.) should not
be discarded in the environment or left within reach of children,
as these are a potential source of hazard. Before beginning the
installation check that the product is in perfect condition.
Do not install the product in explosive areas and atmospheres:
the presence of flammable gas or fumes represents a serious
threat to safety.
The safety devices (photocells, sensitive edges, emergency
stop, etc.) must be installed taking into account: the provisions
and the directives in force, Good Working Methods, the instal-
lation area, the functional logic of the system and the forces
developed by the motorised door or gate.
Before making power connections, check that the rating
corresponds to that of the mains supply A multipolar di-
sconnection switch with a contact opening gap of at least 3 mm
must be included in the mains supply. Check that upstream of
the electrical installation an adequate residual current circuit
breaker and an overcurrent cut out are fitted. When requested,
connect the motorised door or gate to an effective earthing
system carried out as indicated by current safety regulations.
During installation, maintenance and repair operations, cut
off the power supply before opening the cover to access the
electrical parts.
To handle electronic parts, wear earthed antistatic con-
ductive bracelets. The manufacturer of the motorisation
declines all responsibility in the event of components which
are not compatible with the safe and correct operation of the
product. For repairs or replacements of products only original
spare parts must be used.
INSTALLATION WARNING
Secure the control panel permanently. Drill a hole into the lower
side of the container so as to run the cables through it. Secure
the cables, if they are accessible, by means of appropriate
gland plates (not provided by us). Keep the line and motor con-
ductors separate (at least 8 mm) from the control conductors at
the terminal board connection points (for example, by means
of clamps). Connect the line and motor protection conductors
(yellow-green) by means of the transformer and control panel
using the clamp provided. At the end of the installation to close
again the container.
EC DECLARATION OF CONFORMITY
Manufacturer:
DITEC S.p.A.
Address:
via Mons. Banfi, 3
21042 Caronno P.lla (VA) – ITALY.
Herewith declares that the control panel E1T is in conformity
with the provisions of the following EC directives:
Low Voltage Directive 73/23/EEC;
EMC Directive 89/336/EEC.
Caronno Pertusella,
08-01-2007
Fermo Bressanini
(President)
120
TECHNICAL DETAILS
Power supply
Fuse F1, F2, F3
Fuse F4
Motor output
Accessories power
supply
Temperature
Protection degree
Dimensions
APPLICATIONS
E1T
9
210
238
E1T
400 V~ / 50Hz
F8A
F3,15A
400 V~ / 6 A max
24 V= / 0,5 A
-20° C / +55° C
IP55
238x357x120
E1T - IP1897