14
HPAC 42 is a cooling module that should be included
in a system where the main components are the heat
pump FIGHTER 1330 and exchanger module HPAC
42. FIGHTER 1330 has an integrated control system
to regulate the heating/cooling, integrated circulation
pumps and is connected via the HPAC module to the
external collector and the building's distribution system
for heating and cooling.
UG
Ev. badrums-
Possible
radiator
bathroom
radiator
RT 10
VPA
EXP
AV
Shutoff valve
BK/JK
Rock collector/Soil collector
BV
Non-return valve
EXP
Expansion vessel with the requisite
safety equipment
FG
Flow sensor
HR
Auxiliary relay/Contactor with bypass
RG
Return sensor
RT 10
Room thermostat RT 10
System description
Principle of operation
RV
B
VVG
A
SF
FIGHTER 1330
P
The heat exchange from the heat source (rock, ground
or lake) takes place via a closed cooling medium sys-
tem where water mixed with antifreeze circulates to
the heat pump.
Ground water can also be used as a heat source how-
ever, this requires an intermediate heat exchanger
between the HPAC and the ground water.
FG
VXV
AV
BV
A B
A B
I II
5 0 . 0
C
Va r m v a t t e n t e m p e r a t u r
1.0
13.43
P
SF
AV
EXP
BV
AV
BK/JK
RV
Control valve
SF
Particle filter
UG
Outside temperature sensor
VBP3
Heat medium pump 3
VPA
Water heater
VVB/ACK Accumulator with water heater
VVG
Hot water sensor
VXV
Reversing valve
HPAC 42
RG
HPAC
SF
AV