GENERATOR SET OVERLOAD
Never exceed the rated power capacity (Amperes and/or Watts) during conti-
nuous operation. Before connecting and running the generator set, calculate the
electrical power consumption of the electrical equipment (in Watts or Amperes).
This electrical power (in Watts and/or Amperes) is generally found on the identifi-
cation plate of bulbs, electrical appliances, motors, etc. The total of all the powers
of the equipment used should not exceed at any one time the rated power of your
generator set
Note: an electrical appliance (compass saw, drill, etc.) consumes more Watts or
Amperes than the number specified on the identification plate when the motor is
subjected to difficult use. For example, a saw that is to cut an extremely hard mate-
rial consumes 3 to 4 times more Watts or Amperes than the number specified on its
identification plate.
STARTING UP, OPERATING AND SHUTTING DOWN THE GENERATOR SET
Starting of the power generating unit :
1- Turn the fuel cock lever to the «on» position
2- Turn the engine switch to the «on»
position
3- Turn the choke lever to the
position
N.B : The choke is not required to start a warm engine.
4- Pull slowly on the recoil starter until its engaged, then pull it brisky. Check the
condition of the rope. For your safety, if it shows signs of wear, closer to the point
of sale.
5- Warm up the engine.
6-Turn the choke lever back to the operating position.
!
Before starting the engine, do not connect the electric apparatus.
Aplication wattage indicate when each apparatus is used by itself.