Tools and Materials
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before
you start installation. If you encounter any installation or performance problems, please don't hesitate to
contact us. Our phone numbers and website are listed on the back cover. Thanks again for choosing Kohler
Company.
Before You Begin
DANGER: Risk of electric shock. Disconnect power before servicing.
DANGER: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply: Connect
only to a properly-grounded, grounding-type receptacle which is protected by a Ground-Fault
Circuit-Interrupter (GFCI). Do not remove the grounding pin or use a grounding adapter.
DANGER: Risk of electrical shock. For hardwire installations/through-floor electrical supply:
Connect only to a properly-grounded, dedicated 120 VAC, 15 A, 60 Hz circuit protected by a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
CAUTION: Risk of hazardous gases. If a new toilet is not installed immediately, temporarily place a
rag in the floor flange opening.
NOTICE: Follow all local plumbing and electrical codes.
NOTICE: The Canadian Electric Code requires receptacles installed in bathrooms to be located at least 1
meter from a bath or shower if practical, but in no case less than 500 mm. If the installation is in Canada,
install this unit in accordance with the Canadian Electrical Code, Part 1.
Observe all local plumbing and building codes.
Carefully inspect the new toilet for damage.
Water and electrical supplies may installed through either the wall or the floor. For a more aesthetic
look, installation of the supplies through the floor is recommended.
There is a wiring schematic on the inside of the junction box cover.
1035530-2-C
Adjustable
Tape
Wrench
Measure
Wax Seal
T-Bolts
Masking
Knife
Tape
Assorted
Supply Stop
Screwdrivers
2
Kohler Co.