Troubleshooting (cont.)
Symptoms
1.
The toilet flushes 3 times,
then operates normally.
2.
The toilet flushes 5 times.
3.
The toilet fails to operate.
Kohler Co.
Probable Causes
A. The fill valve is not turning off.
B. The motorized valve is not
closing.
A. The level switch has an
intermittent connection.
B. The level switch is stuck in the
up position.
C. The level switch is not properly
connected.
D. The level switch does not move
freely.
A. There is a problem with the
wiring.
B. The GFCI or ELCB is tripped.
C. There is a problem with the
pump connection.
D. The actuation switch is not
properly connected.
E. The level switch is not properly
connected.
The pump assembly does not
F.
work.
G. The actuation assembly does not
work.
15
Recommended Action
A. Repair or replace the fill valve.
B. Repair or replace the motorized
valve.
A. Repair or replace the level switch.
B. Repair or replace the level switch.
C. Reconnect the level switch
properly.
D. Replace the level switch.
A. Check the wiring and connect the
power.
B. Reset the GFCI or ELCB (if
applicable).
C. Check the pump connection.
D. Check the actuation switch
connection.
E. Check the level switch connection.
Replace the pump assembly.
F.
G. Replace the actuation assembly.
1035530-2-C