ZF SERIES PRESSURE WASHER
11. When the machine is working, do not cover or place
in a closed space where ventilation is insufficient.
12. Machines with shut-off spray guns should not be op-
erated with the spray gun in the off position for ex-
tended periods of time as this may cause damage
to the pump.
13. Protect from freezing.
14. Be certain all quick coupler fittings are secured be-
fore using pressure washer.
15. Do not allow acids, caustic or abrasive fluids to pass
through the pump.
16. Inlet water must be from a cold fresh water supply.
17. Do not allow CHILDREN to operate the pressure
washer at any time.
18. The best insurance against an accident is precau-
tion and knowledge of the machine.
19. Landa will not be liable for any changes made to our
standard machines or any components not pur-
chased from Landa.
PRE-OPERATION CHECK
❏ Pump oil (SAE 30W non-detergent oil, General)
❏ Cold water supply ( 6 gpm, 5/8", 20 psi)
❏ Hose, wand, nozzle (nozzle size per serial plate)
❏ Water filter (intact, non restrictive)
SET-UP PROCEDURES
1. Put teflon tape on the inlet fitting (about 3 wraps).
Screw on 3/4" garden hose swivel provided in bag.
Attach a 5/8" garden hose to inlet connector. Mini-
mum flow should be 3 gpm.
Step 1: Connect water suction hose to the INLET
connector. We recommend the use of a reinforced
suction hose with internal diameter not less than
13mm. (1/2 inch)
2. Attach high pressure hose by screwing hose con-
nector to pressure washer outlet, hand tight.
3. Assemble the wand by pushing the two halves to-
gether and then fix by turning the connector to
tighten.
4. Connect wand to trigger gun by turning the connec-
tor. Attach high pressure hose to trigger gun and
tighten.
Step 4: Connect one end of the high pressure
hose to the spray gun (A) and the other to the
outlet connection (B). Assemble lance by
pushing the two halves together and then fix
5. Remove red oil plug on top of pressure washer and
replace with dipstick supplied. Remove plug from red
oil cap anytime the pressure washer is running.
Step 5: Replace the red oil
travel plug (1) with the black and
yellow dipstick (2) in the bag.
6. Check oil level on sight glass on left side of pressure
washer. Oil level should be visible half way up the
sight glass (30 wt. non-detergent). If oil level is not
visible as described, add oil as needed.
OPERATING INSTRUCTIONS
1. With power switch in OFF position, plug power cord
into a grounded receptacle of proper voltage and
amperage reading. Then push GFCI reset button at
end of power cord if required.
2. Turn on water at faucet and pull trigger on spray gun
allowing water to flow until all air has discharged from
system. Check for water leaks; tighten as needed.
3. With trigger spray gun off, turn power switch to ON
position and check for leaks.
LANDA ZF • REV. 9/02
OPERATOR'S MANUAL
by turning the connector.
5
Step 6: Check
that the oil
level in the
sight glass is
at the halfway
level.