Maintenance & Care; Handle Removal - Pfister PORTLAND LG34 Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

18
18 UNIT START UP
Turn on hot and cold water supplies, and check for leaks above and below the sink.
Note: After installation is complete, flush faucet (see step 22).
FAUCET FUNCTIONS
19
19A
19 VALVE FUNCTION
By lifting the Lever Handle (19A) up, the valve will be activated allowing water to flow.
The water flow will increase by continuing to lift up the Lever Handle (19A). By rotating
the Lever Handle counter-clockwise, the water temperature will decrease to cold flow
only. By rotating the Lever Handle clockwise, the water temperature will increased to
hot flow only.
20
20 SPOUT FUNCTION
The Spout (20A) can be rotated around the Faucet Body in any direction.
HOT
COLD
ON
19A
20A
ENGLISH
21
21B
21 SIDE SPRAY OPERATION
The Side Spray (21A) can be pulled forward to spray water in any direction. To activate
the Side Spray, press the Toggle Button (21B) located on the back of the Side Spray
(21A).
MAINTENANCE & CARE
22
22E
22D
22C
22 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (22A). Turn Valve (22B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (22A) by
separating the Aerator Shell (22C), Basket (22D), and Washer (22E). Once parts have
been cleaned, reassemble by reversing steps.
23
23B

23 HANDLE REMOVAL

Turn off water before proceeding! With valve in closed position, detach Decorative
Button (23A), unscrew Fastener (23B), and remove Handle Hub (23C) from Valve Stem (23D).
6
21A
22B
22A
23A
23C
23D
Tabla de contenido
loading

Tabla de contenido