Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
The lower shower must only be activated while a
person is sitting on the bidet for hygienic cleaning
purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The mixer can not used together with a continuous
flow water heater.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 8)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Setting the water volume (see page 9)
Maintenance (see page 11)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions (see page 10)
Flow diagram (see page 10)
max. 1 MPa
0,2 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Assembly (see page 6)
English
Spare parts (see page 12)
Special accessories (order as an extra)
Installation putty (see page 6)
Cleaning (see page 11)
Operation (see page 7)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
65°C