27. Lower platform 1/2 the distance
to ground (FIG. 16-2) by turning
hand pump release valve counter-
clockwise with handle (FIG. 16-1).
Turn release valve fully clockwise
to stop platform from lowering
(FIG. 16-1).
28. Reconnect power to the pump
by reconnecting positive (+) and
negative (-) cables to battery
(FIG. 16-3). Reinstall and tighten
nut when each battery cable is
reconnected.
© MAXON Lift Corp. 2018
Sht. 16 of 48 DSG#
OPENING/CLOSING RELEASE VALVE
PLATFORM
LOWERING PLATFORM WITH HAND PUMP
POSITIVE (+)
BATTERY POST
NUT
NEGATIVE (-)
BATTERY CABLE
RECONNECTING POWER
M-13-05
Date: 07/30/18
FIG. 16-1
FIG. 16-2
POSITIVE (+)
BATTERY CABLE
NEGATIVE (-)
BATTERY POST
FIG. 16-3