14. Install the Apron Access Panel
IMPORTANT! Risk of product damage. Ensure that the tabs are aligned before pressing the apron panel
into place. Improper alignment can damage the clips.
Ensure that the apron area is free from obstructions.
Position the apron panel in the apron frame.
Slide the apron panel tabs up under the apron frame until the tabs engage and all clips align with
the apron frame opening.
Press the center of the apron panel until it snaps into place.
Troubleshooting Table
This troubleshooting guide is for general aid only. An Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Symptoms
1.
Whirlpool does not
start/stop.
2.
Motor starts, but all jets
are not functioning.
3.
Whirlpool stops
automatically.
4.
Noisy operation.
5.
Leakage is detected under
the whirlpool.
1072813-2-A
Apron Frame
Apron Panel
Probable Causes
A. No power to the pump motor.
B. Air actuator does not work.
C. Motor/pump does not work.
A. Jet is closed.
B. Jet is blocked.
A. GFCI trips.
B. Suction blocked.
C. Jets are blocked.
D. Motor overheated and
protection device activated.
A. Pump banding straps have not
been cut.
A. Piping leaks.
B. Sealant or gasket failure at holes
through finished walls, shower
door, or wall surrounds.
Tabs
Clips
Recommended Action
A. Set/Reset the GFCI breaker. Check
the wiring.
B. Replace air actuator. Check air tube
between air actuator and pump.
Replace if necessary.
C. Rebuild or replace motor/pump.
A. Rotate jet trim ring
counterclockwise to open.
B. Remove the blockage.
A. Identify source of fault, and correct.
B. Remove obstruction.
C. Remove blockage.
D. Check for blockage at motor vents.
Remove blockage and allow motor
to cool.
A. Cut pump banding straps with a
pair of tin snips.
A. Repair any piping leaks.
B. Replace any defective gaskets or
seals. Apply clear 100% silicone
sealant as required.
18
Sterling