Connect any panic function, extra ring tone, floor call, auxiliary power and link to IPerHOME system
function wires to the terminals on the external printed circuit.
•
Connect the video door phone to the connector CN1 on the printed circuit board via the cable provided
on the back of the video door phone.
•
Move the video door phone close to the bracket by centring the special fixings 1 and slide it down to
reach its stop 2 (see the following image).
DISTANCES, SECTIONS, CABLES AND TECH SPECS
Type of connection
Call to floor level
Panic Alarm
Call repeating
External power supply
LAN
(*) To ensure longest-range video door phone operation, the cable must be a class 5e device and the
twisted pairs' cross section must be AWG24.
The maximum resistance of the individual wires must not exceed 10 ohm / 100m (10 ohm / 328 ft).
The cable must be up to the following standards:
- EIA/TIA 568-B.2 or EIA/TIA 568-C.2
- EN50288 3-1
- IEC 61156-5
The connection between the IP video door phone and POE switch must be ensured by a single cable
without any extra patch cords.
Wires with cross-section area of 0.5 mm
crosssection area smaller than 0.5 mm
POE input voltage: ..........................................................................................................................48-54 V
External power supply voltage
Max consumption: .................................................................................................................................... 12 W
Display: .................................................................................................................................................. 7" TFT
Touchscreen: .................................................................................................................................. Capacitive
Resolution: ................................................................................................................................ 1024 x 600 px
Brightness: ...................................................................................................................................... 350 cd/m
Viewing Angle (H/V): ....................................................................................................................... 160° / 160°
Operating Temperature: .................................................................................................................. -5 to 45°C
IPerHOME CU Consumption: ................................................................................................................ 0.5 CU
Max number of video door phones on the POE ports of switch 1039/44: ..................................................... 2
DS1717-053A
1
Max distance
30 m / 98 ft
30 m / 98 ft
30 m / 98 ft
25 m / 81 ft
100 m / 328 ft
or larger must comply with IEC 60332-1-2; wires with
2
must comply with IEC 60332-2-2.
2
:................................................................................24 / 48 V
(#)
2
0,5 - 1 mm
0,5 - 1 mm
0,5 - 1 mm
0,5 - 1 mm
Min - max cross section
/ AWG20 - AWG17
2
/ AWG20 - AWG17
2
/ AWG20 - AWG17
2
/ AWG20 - AWG17
2
CAT5e (*)
- min. 15 W
23 ÷ 113 °F
2
5