Technical Data - SFA SANIWELL Manual De Funcionamento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
UK
FR
1. SAFETY
WARNING, This device can be
used by children who are at least
8 years old and by people with
reduced
physical,
mental capacities or those without
knowledge or experience, if they are
properly supervised or if they have
been given instructions on safely
using the device and the associated
risks
have
Children should not play with the
device. Children should not clean or
perform maintenance on the device
without supervision.
ELECTRICAL CONNECTIONS : The
device's power supply must be
connected to ground (class I) and
protected by a high sensitivity
differential circuit breaker (30 mA).
The connection must be used
exclusively to provide the power to the
product.
If the power cord is damaged, to
prevent possible danger, it must
be replaced by the manufacturer,
customer service team or a similarly
qualified individual.
Disconnect
supply before carrying out
work on the unit!
The installation and operation of
your pump must comply with local
standards.
2. AREA OF USAGE
SANIWELL is suitable for conveying clear water
from private private or commercial use.
The size of suspended solids must not exceed
1  mm. The pump must not be used to convey
waste waters containing substances which attack
or damage the pump's materials.
The pump is not approved for conveying waste
waters containing faeces.
3. LIST OF PARTS PROVIDED
See figure 1.
sensory
been
understood.
the
electrical

4. TECHNICAL DATA

Power rating P1
Voltage
or
Frequency
Power input
Speed rotation
Max. discharge flow
Q
max
Max. discharge
height H
max
Max. liquid
temperature
Discharge
connection
Diameter
Total height
Supply cable
Weight with cable
Max. submersion
depth
Max. particle size
Float switch
Length of the float
cable
Materials
Pump housing
Motor housing
Motor shaft
Pump seal
Impeller
This piece of equipment complies with the
directives and European standards on electric
safety and electromagnetic compatibility.
4
40
60
1.0 kW
1.25 kW
1.8 kW
230 V
50 Hz
4.4 A
6.0 A
8.5 A
2850 rpm
5.7 m³/h
43 m
57 m
82 m
35 °C
G 1¼"
127 mm
476 mm
529 mm
649 mm
20 m
12 kg
13 kg
15 kg
20 m
1 mm
Model A : Yes
700 mm
Stainless steel
Stainless steel
Stainless steel
Mechanical seal
Carbon/Ceramic/NBR
PPO GF 20
80
Tabla de contenido
loading

Este manual también es adecuado para:

Saniwell a

Tabla de contenido