What to do when...
... equipment to be controlled does not re-
spond?
• Slide switch in position 'ON'?
• Instabus / IR converter in sight contact with
equipment to be controlled?
• Check the batteries of the remote control
for condition.
• Is the IR key concerned still programmed?
Repeat programming in acc. with
chapter "Programming the remote
control".
• Has the IR memory been deleted
(chapter "Deleting the IR memory")?
Repeat programming in acc. with
chapter "Programming the remote
control".
• IR window flashing green?
Check the position of the slide switch and
move to position 'ON'.
• IR window shining red?
The internal energy source is exhausted
and needs recharging. Wait a few minutes
until the red light goes out. If this is not the
case, contact the EIB installation fitter.
... the remote control cannot be program-
med?
• Check that the remote control can be used
in combination with the Instabus / IR con-
verter (see chapter "Suitable IR remote
controls").
• Check the batteries in your remote control
for condition.
... further EIB appliances – e.g. pushbut-
tons, luminaires, blinds/shutters, etc. – are
to be used in combination with the Insta-
bus / IR converter ?
• The Instabus / IR converter must be repro-
grammed. Contact the EIB installation fit-
ter.
Suitable IR remote controls
The remote controls mentioned below can be
used in combination with the Instabus / IR
converter .
For detailed information, read the Technical
Data of your IR remote control (part of the
operating instructions of the remote control
or of the equipment to be controlled).
The remote controls or the electrical equip-
ment to be used with the Instabus / IR conver-
ter must fulfill the following requirements:
• Infrared remote controls using the RC5 co-
de.
• IR wavelength:
• Carrier frequency: 20...70 kHz and 455 kHz
The following devices cannot be used:
• Remote controls without carrier frequency
of older design
• Radio remote controls and transmitters
• The old Gira IR system cannot be used
either.
920...970 nm
(Bang & Olufsen)
13