Technical Characteristics; Precautionary Measures - Mestra ECLIPSE II Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

is now contaminated with particles eroded off the
parts blasted.
▪ The silencer filters inside the tanks must be replaced
every 5000 or 10000 operations (around 1 or 2
years). The incoming filter fittings on each tank must
be replaced every 500 or 1000 hours (much depends
on the quality and metrage of the sand used). Original
MESTRA spare parts must always be used.
▪ To prevent any abrasion wear on the walls inside the
chamber, take care not to direct the stream of emery
directly onto the walls.
▪ Clean out the emery inside the chamber on a periodic
basis, using the practical emptying plug inside.
▪ Any water which has condensed inside the incoming
air filter must be bled out regularly. The chamber has
a window to view the amount of water in the filter.
▪ Use a dry cloth or a cloth moistened with soapy water
for general cleaning of the unit.
▪ If the guns become obstructed, remove the nozzle-
holder and take out the nozzle. Unblock the nozzle by
blowing in the opposite direction to the flow of air, or
use a pin or a thin wire to unblock it, and then refit
the attachment.
▪ The blasting module guns on the 2-tank Eclipse
model are supplied ex-works with nozzles 1 and 1.25
mm in diameter. 0.75 nozzles, however, may also be
used with this model (consult your MESTRA
distributor).
▪ The maximum diameter of emery particles in relation
to nozzle diameter is shown in the table below:
MAXIMUM PARTICLE DIAMETER /
NOZZLE
Nozzle
Diameter
1.25 mm
Up to 250 microns
1 mm
Up to 150 microns
0.75 mm
Up to 75 microns

Precautionary measures

▪ Never exceed 6 bars of pressure. Optimum working
pressure is between 2 and 2 bars.
▪ Operations should always be carried out with the lid
of the chamber closed, with suitable protection.
Masks and goggles should be worn.
▪ Connect the chamber's outgoing tube to a suction
facility.
▪ The protection sleeves (F) must be replaced
immediately following any tearing or damage.
▪ Do not allow children or unqualified staff to operate
the unit.
▪ Use only guaranteed-quality materials as emery (we
recommend MESTRA emery). Poor quality emery
may be toxic when inhaled, and may also cause
obstructions in the blow nozzles.
▪ Hook up the power supply cable to 230 V, 50/60 Hz,
earthed.
▪ Consult your fitter immediately if any leakages are
observed in the compressed air circuit.
▪ Before carrying out any operation, first ensure that
the micro blasting module covers are closed tightly.
8

Technical characteristics

Height: ...............................................................330 mm
Width: ................................................................360 mm
Length: ...............................................................450 mm
Weight: ................................................................. 5.7 kg
Working pressure: .............................................. 2-6 bar
Voltage: ............................................... 230 V, 50/60 Hz
Power consumption: ................................................ 7 W
Air connection: ................................................... Ø6 mm
Declaration of conformity UE
The firm Talleres Mestraitua S.L.
with social address: Txori-erri Etorbidea, 60
48150 Sondika - Bilbao - Spain
Hereby declares that the product
Sandblaster Eclipse 080220
Meets the requirements set out in the following
directives:
2014/35/UE (low tension)
2014/30/UE (electro magnetic compatibility)
Ignacio Mestraitua
Managing Director
Sondika, 2019-09-11
Tabla de contenido
loading

Este manual también es adecuado para:

080220

Tabla de contenido