26 • ENGLISH
BATTERIES
BLACK+DECKER batteries can be recharged
many times. At the end of their useful life, discard
batteries with due care for our environment:
f Run the battery down completely, then remove it from
the tool.
f NiCd, NiMH and Li-Ion batteries are recyclable.
Take them to any authorized repair agent or a local
recycling station.
SPECIFICATIONS
Voltaje
No-load speed
Torque
Chuck
CHARGER
Output voltage
Input voltage
AR
B2C
B3
BR
Current 400 mA
Charge time
PROBLEM
Unit will not start.
Battery packwill not charge.
Unit shuts off abruptly.

SERVICE INFORMATION

BLACK+DECKER offers a full network of company-owned and authorized service locations. All BLACK+DECKER
Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool service.
For more information about our authorized service centers and if you need technical advice, repair, or genuine factory
replacement parts, contact the BLACK+DECKER location nearest you, or visit us at www.BlackandDecker-la.com
LD120
20 V
MAX*
0 - 650/min (rpm)
25Nm (18,4 ft-lb)
3/8" (10mm)
8 V - 20 V
220V ~ 50Hz
220V ~ 50/60Hz
120V ~ 60Hz
127V/220V ~ 60Hz
3 - 4hr

TROUBLESHOOTING

POSSIBLE CAUSE
Battery pack not installed properly
Battery pack not charged.
Battery pack not inserted into charger.
Charger not plugged in.
Surrounding air temperature too hot
or too cold.
Battery pack has reached its
maximumthermal limit.
Out of charge. (To maximize the life
of the battery pack it is designed to
shut off abruptly when the charge is
depleted.)
BATTERY
Voltage
Capacity
Type
* Maximum initial battery pack voltage (Measured without
a workload) is 20 volts. Measured under a workload,
nominal voltage is 18V.
POSSIBLE SOLUTION
Check battery pack installation.
Check battery pack charging
requirements.
Insert battery pack into charger until
green LED appears
Plug charger into aworking outlet.
Refer to "Important Charging Notes"
formore details.
Move charger and battery pack to
a surrounding air temperature of above
40°F 4,5°C) or below 105°F (+40,5°C).
Allow battery pack to cool down.
Place on charger and allow to charge.
LD120BAT
20 V
MAX*
1,5Ah
Lithium-Ion