Technical Data
Rated Power
Max. delivery capacity
Max. pressure
Max. delivery height
Max. submersion depth
Flat submersion height approx.
Contaminated water with particle size of max.
Power cable
Fitting
Min. water level for operation
Weight approx.
Max. media temperature
Voltage/Frequency
Cut-in height
Cut-out height
¡ATTENTION! The cut-in and cut-out height vary, The indicated values, are average values and are not valid
when the float switch is not fixed to the float switch lock (3).
Information
Follow the information given. Use the operating
instructions to get acquainted with the proper use of
your submersible pump.
For safety reasons, people who are not familiar with
these operating instructions should not use this
submersible pump.
Following the operating instructions supplied by the
manufacturer is a prerequisite for the proper use of
the pump.
Application range
Submersible pumps have been designed for private
use around your house and garden. Submersible
pumps are predominantly used for drainage after
folding, transfer of liquids, draining containers,
taking water from wells and shafts, draining
boats and yachts as well as for water aeration and
circulation for limited period of time.
The pump is fully submersible (waterproof sealed)
and can be submerged down to a depth of 5 m into
the liquid.
Liquids which can be handled by the Submersible
Pump are the following clean or slightly contaminated
water (max. particle size 5 mm. or 0,5 mm.) and soapy
water.
10
Please read these operating
instructions carefully.
400 W.
8000 l/h.
0,5 bar.
5 m.
5 m.
5 mm.
35 mm.
10 m. H05RN-F
32mm(5/4")-/25mm(1")-universal fitting, option hose
connection system parts
7 cm.
5 kg.
35 ºC.
230V,50Hz 120V,60Hz
53 cm.
10 cm.
Corrosive, easily combustible or explosive
substances (e.g. gasoline, petroleum,
nitro thinner), fats, oils, salt and waste
water of toilets and urinals must not be
pumped. The temperature of the liquid handled
should not exceed 35°C.
The pump is not designed for continuous operation
(e.g. continuous circulating operation); your pump's
life will be shortened correspondingly by such
operation.
Measures before operation
Hose Connection
Screw the supplied fittings onto the pump, as
described in (page 5). The universal fitting (7) allows
connection of 32 mm. (514"), 25 mm. (1"), 19 mm.
(3/4") as well as of 13 mm. (1/3") hoses, according
to your individual requirements, 32 mm. (5/4") hoses
are connected to the pump via the step nipples of
the universal fitting, 19 mm. (3/4") and l3 mm. (1/2")
hoses with Hose connection system parts (page 5). It
is recommended to fox 32 mm. (5/4") and 25 mm.
(1") hoses additionally with a hose clamp.
Components of the universal fitting which you don't
require (when connecting 32 mm. (1/2") hoses are
detached with a knife from the universal fitting
(page 5).
Best results in delivery capacity are achieved when
using 32 mm. (5/4") hoses.
ENGLISH