5.7. Precautionary measures to be taken by the operator
IBS-Parts Cleaning Devices conform to type class A 1 (EN 12921-3; 3.15.1).
A danger area which is appropriate for the operating conditions (e.g. geometry and surface area of workpieces, intensity
of cleaning) must be defined. For normal cleaning processes, IBS recommends a danger area of 2 m around the device.
DANGER!
The danger area identified by means of a risk assessment:
∙
Must be designated a fire hazard area
EN
∙
Must remain free of obstructions in order to allow unimpeded access at all times
∙
Must be equipped with effective natural ventilation
∙
Smoking is not permitted in the danger area
∙
Naked flames or other sources of ignition are not permitted in the danger area
∙
Keep everything as clean as possible when working with cleaning agents, oils and lubricants
∙
Operating and maintenance personnel must receive proper training
∙
The operating instructions and the standard operating procedure must be attached to the device
6. OPERATING THE MACHINE
6.1. Controls
The device is switched on with a foot-operated safety switch.
6.2. Assembly and adjustment
6.2.1. Assembling the Parts Cleaning Device M and MD (M-500 see attachement)
∙
Remove the packaging.
∙
Insert the two base frames (1) into the round pipe sleeves (2) (located directly underneath the tray).
∙
Attach the two cross braces (3) to the base frames using the bolts supplied (4).
∙
Place the 200-litre drum (5) in the collecting tray (optional) (6) with the screw fitting facing upwards and remove the 2" bung adapter
in the drum casing.
∙
Place the assembled device over the drum (5).
56
IBS-BA_Typ_M_MD_M500-DE_CZ_PL_ES_EN_04.2020
13
2
4
1
6
11
10
3
9
5
7