5.7. Precautionary measures to be taken by the operator

IBS-Parts Cleaning Devices conform to type class A 1 (EN 12921-3; 3.15.1).
A danger area which is appropriate for the operating conditions (e.g. geometry and surface area of workpieces, intensity
of cleaning) must be defined. For normal cleaning processes, IBS recommends a danger area of 2 m around the device.
DANGER!
The danger area identified by means of a risk assessment:
Must be designated a fire hazard area
EN
Must remain free of obstructions in order to allow unimpeded access at all times
Must be equipped with effective natural ventilation
Smoking is not permitted in the danger area
Naked flames or other sources of ignition are not permitted in the danger area
Keep everything as clean as possible when working with cleaning agents, oils and lubricants
Operating and maintenance personnel must receive proper training
The operating instructions and the standard operating procedure must be attached to the device

6. OPERATING THE MACHINE

6.1. Controls

The device is switched on with a foot-operated safety switch.

6.2. Assembly and adjustment

6.2.1. Assembling the Parts Cleaning Device M and MD (M-500 see attachement)
Remove the packaging.
Insert the two base frames (1) into the round pipe sleeves (2) (located directly underneath the tray).
Attach the two cross braces (3) to the base frames using the bolts supplied (4).
Place the 200-litre drum (5) in the collecting tray (optional) (6) with the screw fitting facing upwards and remove the 2" bung adapter
in the drum casing.
Place the assembled device over the drum (5).