Technical parameters
Supply terminals:
Supply voltage tolerance:
Consumption:
Max. dissipated power
(Un + terminals):
Supply voltage:
Real time back-up:
Backup battery type:
Summer/winter time:
Output
Number of contacts:
Rated current:
Switched capacity:
Switched voltage:
Mechanical life:
Electrical life (AC1):
Time circuit
Real time back-up when
de-energized:
Accuracy:
Minimum interval:
Program data stored for:
Program circuit
Illumination range:
Sensor failure indication:
Number of program places:
Program period:
Data readout:
Other information
Operating temperature
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage cathegory:
Pollution degree:
2
Max. cable size (mm
):
Dimensions:
Weight:
Dimension of sensor:
Weight sensor:
Standards:
* ERROR - sensor short circuit
Light sensor
Sensor resistance upon:
<1 Lux
1 Lux
100 Lux
50 000 Lux
Sensor for SOU-2 is external and is connected to terminals T1.
Sensor is installable to panel (by screw-able transparent cover) to opening with diameter 16 mm.
A part of the sensor is a plastic holder for placing into the wall or to another place. Length of a
line connector to the sensor cannot be more than 50 m. Doublecure cable can be used as wire
2
diameter min. 2x 0.35 mm
and max. 2x 2.5 mm
Protection degree is IP44. To keep this protection:
- photoresistor cover must be sealed by a rubber circle (part of the sensor)
- cable must be of round cross-selection
- the opening must be tight to the used cable
It is possible to use photoresistor, which changes resistance in accordance with ambient illumi-
nation, as a sensor. Tolerance sensor ± 33 %.
SOU-2
A1 - A2
AC 230V / 50 - 60Hz
max. 4 VA / 1.5 W
3 W
-15 %; +10 %
yes
CR 2032 (3V)
automatic
1x changeover (AgSnO
)
2
8 A / AC1
2000 VA / AC1, 240 W / DC
250 V AC / 30 V DC
3x10
7
5
1x10
up to 3 years
max. ±1s/ day at 23 °C
1 min.
min. 10 years
10-50000 Lux
displayed on LCD*
100
daily, weakly, yearly
LCD display, with back light
-10.. +55 °C
-30.. +70 °C
4 kV (supply - output)
any
DIN rail EN 60715
IP 40 z from front panel / IP 20 clips
III.
2
max. 1x 2.5, max. 2x 1.5 /
with sleeve max. 1x 1.5
90 x 35 x 64 mm
139 g
66 x Ø 23.5 mm
15 g
EN 61812-1, EN 61010-1,
EN 60255-6, EN 60730-1, EN 60730-2-7
Value
> 3 MΩ
3 MΩ
1150 Ω
51 Ω
2
.
Mode precendence
mode precedence
mode with the highest

priority

Light and Time Program can work at the same time on a single channel.
Control description
Device diff ers short and long button press. In the manual marked as:
- short button press (<1s)
- long button press (>1s)
After 30s of inactivity (from the last press of any button) will device automatically returns into
starting menu.
In the start screen, press
to toggle between displaying the date or light intensity.
OK
The measured value after exceeding 999 is measured in the hundreds of thousands by display-
ing the letter „k" at the end. A comma separates the thousands line.
Language settings
Auto
PRG
Prog
Prog
Prog
LIGHT
options
language
+ _
OK
options
Language
selection
2 / 7
display
output mode
ON / OFF
manual control
ON / OFF 
holiday mode
ON / OFF
time program
light
light
entrance into programming menu
PRG
browsing in menu
+ _
setting of values
+ _
quick shifting during setting of values
entrance into required menu
confi rmation
OK
switch. between display
one level up
ESC
a step back
back to the starting menu
ESC
Prog
ESPAnOL
Prog
Prog
OK
Prog
Prog
+ _
Prog
Prog
Prog
language
OK
ESC