Ford M-10665-A Manual página 8

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall
socket.
2. FLASHING LIGHT:
The charger has entered the energy save
mode. This happens if the charger isn´t con-
nected to the battery within 2 minutes or the
battery on board UVP (under voltage protec-
tion) is activated.
READY TO USE
The table shows the estimated time for an empty
battery to reach 90% state of charge (SOC).
Please note that charging times are
longer in low ambient temperatures.
BATTERY SIZE (AH)
40Ah
60Ah
100Ah
10 • EN
TIME TO 90% CHARGED
6h
9h
15h
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected
to the battery's positive pole?
2. Is the charger connected to a 12V
Lithium Ion battery?
3. Are the terminals short circuited?
4. Has charging been interrupted in
or
?
Restart the charger by pressing/holding the
RESET button. If charging is still being inter-
rupted, the battery...
...can not accept charge.
...may be too large for the charger to wake
up. Press/hold RESET button for 10 seconds
up to 5 times.
...a parallel load may be connected to the
battery. Disconnect the battery and try
again.
...can not keep charge and may need to be
replaced.
Tabla de contenido
loading

Tabla de contenido