TUBE REPLACEMENT
INSTALL THE PUMP TUBE AND EXPAND THE ROLLER ASSEMBLY
IMPORTANT! DO NOT LUBRICATE PUMP TUBE OR ROLLER ASSEMBLY.
1. Place the new tube in the pump head, use your fingers to ensure that it centered over
the rollers. Illustration I p26
2. Place the tube housing cover on the tube housing, affix the front of the latches to the
cover lip and then press the latches to secure. Be sure the cover is seated with the
sleeve bearing on the shaft and is flush with housing, before latching. Illustration J p26
3. With the cover latched, attach the power supply and turn the pump on. Allow the
pump to run the roller assembly in its collapsed position for one minute to relax the
tube. Illustration K p26
4. Turn the pump off and disconnect the power cord.
5. Remove the tube housing cover and flip to use as a tool in the next step.
Illustration L p26
6. Align the center of the inverted cover with the center of the roller assembly so that the
three holes on the face of the cover align with the three knurled lugs on the roller
assembly. Position the cover feet near the bottom. Illustration M p26
NOTE: The roller assembly needs to be expanded to the tube is pressed against the
tube housing wall.
7.. Hold the pump securely. Use the cover as a wrench and quickly (snap) rotate the roller
assembly clockwise to expand the roller assembly. The tube will be pressed against the
tube housing wall. Illustration N & O p26
NOTE: Clockwise is viewed from facing the head of the pump.
8. Apply a small amount of AquaShield
pump tube. Illustration P p26
9. Place the tube housing cover (feet first) on the tube housing, affix the front of the
latches to the cover lip and then press the latches back to secure. Be sure the cover is
seated with the sleeve bearing on the shaft and is flush with housing, before latching.
Illustration Q p26
US and Canada 800.683.2378, International 904.641.1666
continued
to the cover bushing ONLY. DO NOT lubricate the
®
27