- When using the 300 mm dorsal attachment extension band with a built-in shock absorbing lanyard
(EN 355), check that the overall combination does not exceed 2m.
- Before every use of a fall-arrest system, the empty space (clearance) required under the user must be
verified so that, in case of a fall, there is no collision with the ground, or with a fixed or moving obstacle
that is within the fall trajectory.
- Via a visual inspection, verify that the equipment is in good condition and that there are no faults:
condition of the straps, seams, adjustment buckles and rings. Ensure that there is no wear, cuts,
fraying, chafing, deformation, traces of rust or discoloration and ensure that the markings are readable
(identification and/or date of validity). Ensure that the buckles are clean and that they function properly.
USE :
- During use, regularly check the fastening and adjustment parts of the harness and the integrated
belt. These components must be protected from any environmental stress: mechanical stress (impacts,
sharp edges, etc.), chemical stress (projection of acids, bases, solvents, etc.), electrical stress (short-
circuit, electric arcs, etc.) or thermal stress (hot surfaces, blowtorches, etc.).
- The fall arrest system must be attached to the dorsal D ring or to the sternal keepers. These points are
identified by letter A (single snap hook) or A/2 (Attachment to connect with each other).
- The use of the harness with a fall-arrest subsystem must be compatible with the instructions for use
of each component of the system and with the standards: EN353-1 / EN353-2 / EN 355 / EN360 / EN
362. For mobile fall-arrest systems including a rigid (EN353-1) or flexible (EN353-2) belay support, it is
recommended to connect the harness using the sternum anchor points. For energy absorbers (EN355)
or self-retracting fall-arrest systems (EN360), connect the harness to the dorsal anchor point.
- The anchor point on the structure used to fix the fall-arrest system must be slightly above the user,
and must comply with the minimum resistance requirements specified in the EN 795:2012 standard (R
≥ 1200 DaN). Try not to distance yourself too much from this anchor point in order to limit the impact
of a possible pendulum fall.
- When using a lanyard for work positioning and restraint, its anchor point must be located at the waist
or above. This lanyard must be kept tight.
- The two side hooking dice must always be used together when connecting with this lanyard. Please
note that the connections are made via connectors in accordance with EN 362.
- The tool-holder rings must not be used as anchor points or work positioning points under any
circumstances.
- After a fall, the harness must be destroyed.
- The use of the belt fitted with connectors with screw gate locking is accepted only if the user does not
have to lock or open the connector too frequently that is to say several times on the same working day.
If this is the case, it will be better to use a connector with an automatic locking.
- A connector must never have a load on its clasp.
GENERAL CONDITIONS OF USE :
- A periodic inspection carried out by a competent inspector is necessary to ensure the safety of the
user, which is connected to the maintenance of the effectiveness and resistance of the equipment. A
mandatory annual inspection will check the condition of the equipment and it can only continue to be
used on obtaining a written agreement.
- Do not expose these products to temperatures less than -30°C or more than +50°C.
- This equipment must not be used in any way contrary to these specifications and under no
circumstances should its limits be exceeded.
- Storage: the product must be stored in a dry and well-ventilated area, sheltered from any direct or
indirect source of heat and from ultra-violet rays. Drying wet equipment must be performed in the
same conditions.
- Cleaning and disinfection: exclusively with water and a neutral soap.
- Packaging: use rot-proof and watertight protective packaging.
- Transport: packaged and sheltered from impacts or pressure caused by the environment.
- The product must not be modified or repaired.
- Service life: Fall-protection PPE are designed to last for several years in normal conditions of use and