Front Panel Features - Furman SmartSequencer CONTRACTOR Serie Guia De Inicio Rapido

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FRONT PANEL FEATURES

COVER SHIELDS REMOVED
START
SEQUENCE
START SEQUENCE
PUSH BUTTON
START SEQUENCE PUSH BUTTON
Triggers sequence in remote mode.
• Activates or deactivates sequence
• Hold button to re-sync multiple sequencer
PRIMARY LINK
PRIMARY LINK
DELAY 1
DELAY 1
START
START
SECONDARY LINK
SECONDARY LINK
DELAY 2
DELAY 2
SEQUENCE
SEQUENCE
ETHERNET
ETHERNET
DELAY 3
DELAY 3
DELAY INDICATORS
Duplex 1 is powered on
DELAY 1
Duplex 2 is powered on
DELAY 2
DELAY 3
Duplex 3 is powered on
Delay 3 contacts react in time with DELAY 3 Outlets
DIP SWITCH MATRIX AND TIME CALIBRATION (diagrams below)
1M = 1 Minute Delay
DIP 1
DIP 2
2M = 2 Minute Delay
DIP 3
4M = 4 Minute Delay
NOTE: DIP 1, 2 & 3 can be summed together up to 7 minutes.
DIP 4
N.O. / N.C. sets Forced Off alarm poles
The out of the box factory setting is "normally open".
When sequence is "ON". Switched outlets will be ON
until a dry contact closure is applied across the
FORCE OFF poles. Note: The FORCE OFF feature is only
available on the Primary sequencer (DIP 8 = ON)
DIP SWITCH CLOSE-UP
1
2
3
4M
1M
2M
DLY
ADJ
GND
MOM
PRI
ON
MNT
SEC
6
7
3
PRIMARY LINK
DELAY 1
SECONDARY LINK
DELAY 2
ETHERNET
DELAY 3
CONNECTION STATUS
LIGHTS
BASIC POWER MANAGEMENT
• UNSWITCHED OUTLET - 15A Courtesy Outlet
CN-1800S & CN-2400S
s
• CIRCUIT BREAKER- Press to reset in the event of
current overload.
1
1
2
2
3
3
4
4
5
5
12V ON
POWER
POWER
1M
1M
2M
2M
PRIMARY LINK
PRIMARYLINK
4M
4M
N.O.
N.O.
12V ON
DELAY 1
DELAY 1
N.C.
N.C.
12V OFF
12V OFF
DLY
DLY
SECONDARY LINK
SECONDARY LINK
PROTECTION OK
DELAY 2
PROTECTION OK
DELAY 2
ADJ
ADJ
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
ETHERNET
ETHERNET
DELAY 3
DELAY 3
GND
GND
MOM
MOM
PRI
PRI
EVS AUTO
EVS AUTO
EXTREME VOLTAGE
EXTREME VOLTAGE
ON
ON
MNT
MNT
SEC
SEC
MANUAL
MANUAL
6
6
7
7
8
8
9
9
POWER PROTECTION INDICATORS
POWER
"Unswitched" outlets are active.
PROTECTION OK
illuminate if surge protection has been compromised.
DIP 5
Remote Mode (DIP 7 set to MNT)
Chooses +12V to REM pole functionality. In default
OFF mode, a dry closed contact across +12V to REM
triggers sequencer OFF. If ON mode, closed contact
triggers ON.
• 12V OFF = Short Deactivates
• 12V ON = Short Activates
DIP 6
Activates REM to GND pole functionality.
• REMOTE TO GROUND = ON
4
5
FACTORY DEFAULT SETTINGS - SET FOR 30 SECOND DELAY
N.O.
12V ON
N.C.
12V OFF
POTENTIOMETER DEFAULT
SETTING - Time Delay
Adjustment is set at
12:00 o'clock (50%)
Time Delay Adjustment ranges from 0.0%
EVS AUTO
to 100%. The percentage is multiplied
MANUAL
8
9
with the DIP switch selections 1, 2 and 3.
DELAY ADJUSTMENT
1
2
3
4
5
N.O.
12V ON
1M
2M
4M
N.C.
12V OFF
DLY
ADJ
1 2 3 4 5 6 7 8 9
GND
MOM
PRI
EVS AUTO
ON
MNT
SEC
MANUAL
6
7
8
9
DELAY
DIP SWITCH
POWER
INDICATOR
MATRIX
INDICATOR
LIGHTS
LIGHTS
UNSWITCHED
UNSWITCHED
4
5
6
7
8
9
1
2
3
1
2
3
4
5
N.O.
12V ON
GND
MOM
PRI
EVS AUTO
15 AMPS
15 AMPS
2M
4M
1M
4M
ON
N.O.
MNT
12V ON
SEC
MANUAL
1M
N.C.
2M
12V OFF
N.C.
12V OFF
DLY
DLY
ADJ
ADJ
1 2 3 4 5 6 7 8 9
GND
MOM
PRI
EVS AUTO
1 2 3 4 5 6 7 8 9
ON
MNT
SEC
MANUAL
6
7
8
9
PUSH TO RESET
PUSH TO RESET
Indicates unit is receiving AC power and
Normally lit, dims or will not
12VDC ON/OFF sets +12V pole in
GROUND ON / OFF
DLY
ADJ
UNSWITCHED
15 AMPS
POWER
PROTECTION OK
EXTREME VOLTAGE
PUSH TO RESET
UNSWITCHED
CIRCUIT
OUTLET
BREAKER
KEYSWITCH SETTINGS
3 position ON/OFF Security Switch
• OFF = Bypasses remote sequenced outlets to OFF
• REMOTE = Engages and activates remote features
• ON = Bypasses remote sequenced outlets to ON
NOTE: Settings affect COMM port (see full manual)
UNSWITCHED
UNSWITCHED
REMOTE
REMOTE
20 AMPS
15 AMPS
POWER
POWER
PROTECTION OK
PROTECTION OK
OFF
OFF
ON
ON
EXTREME VOLTAGE
EXTREME VOLTAGE
PUSH TO RESET
PUSH TO RESET
EXTREME VOLTAGE
voltage condition is present (consequently, all outlets
are powered off). EVS auto reset is controlled by
(DIP 9) setting.
Maintained / Momentary
DIP 7
Sets contact closure preference for either
Maintained or Momentary switches.
NOTE: Momentary mode overrides DIP 5 and 6.
DIP 8
PRIMARY / SECONDARY
Delegates unit's role in command sequence.
DIP 9
EVS AUTO / MANUAL setting
Activates/Deactivates Extreme Voltage Shutdown
Auto Reset. Manual setting requires Key Switch
to be set OFF to clear EVS state. Note: Second-
ary sequencers follow the EVS clearing behavior
of the Primary Sequencer regardless of the
setting of DIP 9.
NOTE: The DIP switch
DIP SWITCH DEFAULT SETTING -
ON / OFF settings are
Switches are factory pre-set as shown
ON
below. Switches 1, 4, 8, and 9 are up
indicated as shown
below throughout
(ON) position.
this manual.
ON
1
2
3
4
5
6
7
8
DLY
ON
ADJ
OFF
1
KEYSWITCH
REMOTE
OFF
ON
REMOTE
REMOTE
OFF
OFF
ON
ON
Illuminated when an extreme
9
2
3
4
5
6
7
8
9
Tabla de contenido
loading

Este manual también es adecuado para:

Smartsequencer cn-1800sSmartsequencer cn-2400s

Tabla de contenido