9.
Troubleshooting
The motor does not start.
No power or low voltage. Check the power line and voltage.
o
Faulty or damaged power cord. Check and replace if needed.
o
Faulty motor/capacitor. Check and replace if needed.
o
The device is locket out due to previous overheating. Detect the cause, let the device cool down and
o
restart.
The motor runs but the device does not ignite.
Empty fuel tank, dirty or wrong fuel. Fill the tank, or remove the wrong fuel.
o
Clogged fuel filter. Clean or replace the filter.
o
Air leaks in the oil line. Check the hoses and tighten the connections.
o
Fuel viscosity increased at low temperature. Mix the diesel with 10-20 % kerosene.
o
Flames escaping from the outlet.
Insufficient airflow into combustion chamber. Check the air inlet, fan and motor.
o
Compressor pressure too high. Check the air pressure and adjust.
o
The device stops during operation.
The room temperature has reached the thermostat setting. This is normal.
o
Flame failure, bad combustion, reduced airflow, overheating. Reset the device.
o
10.
Technical Specifications
power supply ............................................................................ 220-240 V~, 50 Hz, 230 W
fuel .......................................................................................................... diesel/kerosene
IP rating ................................................................................................................... IPx4
FT120C
power ................................................................................................................... 20 kW
heat output ................................................................................................... 68240 BTU/h
fuel tank capacity ...................................................................................................... 19 L
heating surface ..................................................................................................... 400 m²
fuel consumption ................................................................................................. 1.96 L/h
air flow ..............................................................................................................550 m²/h
dimensions ........................................................................................ 750 x 315 x 415 mm
weight .................................................................................................................... 14 kg
FT130C
power ................................................................................................................... 30 kW
heat output ................................................................................................... 10236 BTU/h
fuel tank capacity ...................................................................................................... 38 L
heating surface ..................................................................................................... 500 m²
fuel consumption ................................................................................................. 2.80 L/h
air flow ..............................................................................................................720 m²/h
dimensions ........................................................................................ 880 x 456 x 590 mm
weight .................................................................................................................... 21 kg
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device. For more info concerning this
product and the latest version of this manual, please visit our website www.perel.eu. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.
V. 01 – 12/05/2017
FT120C/FT130C