6- Electrical Wiring Harnesses; 7- User Manual - Vimar Elvox EIM1 Manual Para El Conexionado Y El Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
HIDDY
Electrical wiring harnesses: take the actuator cable to the watertight junction box (cable length 2 metres) and do the wiring according to the diagram:
Wire colour
White
Blue
Brown
Red
Black
The electrical wiring between the control unit and the actuator must not exceed 15 metres
User Manual
Manual unlocking: In the event of mains power failure, the back-up battery ensures the operation of the automatic gate system for a limited period. If the
battery is discharged or not installed, manually unlock the actuator using the unlocking lever.
1. Remove the plastic cap
2. Insert the lever and rotate it by 90° until the gate leaf is freed
3. The gate leaf is unlocked and opens with a slight pressure.
4. Remove the lever and put the cap back on.
5. Repeat operations 1 to 4 for the second gate leaf, if present.
- To return to automatic operation:
1. Remove the plastic cap
2. Insert the lever and rotate it 90° anticlockwise
3. Move the gate leaf into the coupling position and turn the lever 90° clockwise
4. Remove the lever and put the cap back on.
5. Repeat operations 1 to 4 for the second gate leaf, if present.
EN
Description
Encoder signal
Encoder supply voltage negative (GND)
Encoder supply voltage positive (+12 Vdc)
Motor supply voltage
Motor supply voltage