Preparation for assembly
1.
Remove the packaging from the kit, retaining the assembly pack and instructions.
2. Thoroughly read the pump owner's manual to familiarize yourself with its operation.
3. Models with telescoping discharge (515801, 515835): Once the old assembly has been removed,
measure the distance from the bottom of discharge to the bottom of the cover plate (Dimension A)
then adjust the discharge on the new retrofit assembly to the same height. Follow these steps to adjust
the discharge height:
a. Loosen the set screw on the pipe collar located below the cover plate.
b. Raise or lower the discharge pipe to the desired height.
c.
Reposition the pipe collar against bottom of cover plate then tighten set screw.
4. Remove the nameplate from the cord and set it aside.
5. Apply gasket tape to the bottom perimeter of the plate assembly.
6. Use an awl or similar tool to poke through the gasket tape at the bolt holes on the plate assembly
perimeter. This will allow the bolts to be installed through the cover and into the basin.
7.
Apply Magic Lube (included) to the O-rings on the discharge assembly to help the component slide
into place.
Placement in Basin
1.
Use the rope to lift the kit into the basin and lower it into place.
2. Align the tabs on the plate to the slots on the basin.
3. Align the discharge fitting to the ball valve on the basin, and lower in completely. The assembly should
rest on the plate, with the discharge fitting nesting into the existing ball valve fitting.
4. Connect the 6-pin plug and receptacle, and tighten the screws.
5. Install the 6 bolts (included) through the plate and into the basin, then tighten them.
6. Restore electricity to the panel and pump.
7.
Fill the basin with water and observe that the pump operates properly. If the pump does not operate
properly, refer to the troubleshooting section of the pump owner's manual.
8. Replace the basin lid and lock the unit, if applicable.
9. Affix the pump nameplate (included) to the existing control box or panel so that the pump can be iden-
tified.
INSTALLATION
Preparation for assembly
3