Velux INTEGRA KLI 110 Manual De Instrucciones página 9

Ocultar thumbs Ver también para INTEGRA KLI 110:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

kLI 110
1
kLC 500
2
kLC 500
3
kLI 110
L R
4
kLC 500
16 VELUX
®
kLC 500
1 sec
1 sec
L R
Set-up of kLI 110 to operate products connected to control unit
kLC 500
Disconnect control unit KLC 500 from power outlet and remove
1
cover. Temporarily disconnect product cables for products not to be
operated by this control keypad KLI 110.
Reconnect control unit KLC 500 to power outlet and press test but-
2
ton for 1 second.
Caution: Press test button for 10 seconds if you want to delete all
previous set-ups.
When one of the products runs briefly back and forth, press button R
3
on control keypad KLI 110 for 1 second.
Note: Steps 2-3 must be completed within 10 minutes.
Disconnect control unit KLC 500 from power outlet, reconnect all
4
disconnected cables and replace cover. Reconnect control unit
KLC 500 to power outlet.
Repeat steps 1-4 for each additional control keypad KLI 110.
The products can now be operated by KLI 110.
VELUX
17
®

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Kli 110

Tabla de contenido