Safety Advice Concerning Replacements; Changing And Replacing The Drilling Cups - Checchi & Magli WOLF COMPACT Serie Manual De Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Safety advice concerning replacements

When replacing worn or damaged parts, original
spares must always be used.
Special maintenance operations (non included in
this handbook) require a specialised workshop on

Changing and replacing the drilling cups

Caution
To prevent damage to the transplant unit transmis-
sion, use the driving wheel to rotate the dispenser.
UN41 0122BM
Proceed as outlined below.
1)
Lift the work vehicle off the ground.
2)
Unscrew the screws (A).
3)
Remove the casing (B).
4)
Unscrew the screws (C) on each drilling cup (D) and
remove it.
English language
INFORMATION CONCERNING REPLACEMENTS
the premises which meets the requirements speci-
fied by the relative laws in force (appropriate equip-
ment suitably trained staff etc.); if you do not have a
compliant workshop, contact an authorised one.
The dispenser can have up to six drilling cups fitted on
it.
A
5)
6)
7)
8)
30
D
C
C
Set up the drilling cup control disk and any phasing
units required (see "Drilling cups arrangement").
Fit the cups in the housings.
Tighten the screws (C) on each drilling cup.
Fit the casing (B) and tighten the screws (A).
Lower the work vehicle onto the ground.
8
C
A
B
Use and maintenance
Tabla de contenido
loading

Este manual también es adecuado para:

Wolfcompact/3Wolf com pact/4Wolf compact/5Wolf compact/6

Tabla de contenido