Checking the Height Accuracy of the Horizontal Line
For this check, you will need a free measuring distance of
5 m on firm ground between two walls (designated A and B).
– Mount the measuring tool close to wall A on the holder or
a tripod, or place it on a firm, level surface. Switch on the
measuring tool with the automatic levelling function en-
abled and select cross-line mode.
A
5 m
– Aim the laser at the closer wall A and allow the measuring
tool to level in. Mark the middle of the point at which the
laser lines cross on the wall (point I).
A
180°
– Turn the measuring tool 180°, allow it to level in and mark
the point where the laser lines cross on the opposite wall
B (point Ⅱ).
– Position the measuring tool – without rotating it – close to
wall B, switch it on and allow it to level in.
A
– Align the height of the measuring tool (using the tripod or
by placing objects underneath as required) so that the
point where the laser lines cross exactly hits the previ-
ously marked point Ⅱ on wall B.
Bosch Power Tools
A
d
B
– Turn the measuring tool 180° without adjusting the
height. Aim it at wall A such that the vertical laser line runs
through the already marked point Ⅰ. Allow the measuring
tool to level in and mark the point where the laser lines
cross on wall A (point Ⅲ).
– The discrepancy d between the two marked points Ⅰ and
Ⅲ on wall A reveals the actual height deviation of the
measuring tool.
The maximum permitted deviation on the measuring dis-
tance of 2 × 5 m = 10 m is as follows:
10 m × ±0.3 mm/m = ±3 mm. The discrepancy d between
points Ⅰ and Ⅲ must therefore amount to no more than
3 mm.
B
Checking the Level Accuracy of the Horizontal Line
For this check, you will need a free area of 5 × 5 m.
– Mount the measuring tool in the middle between walls A
and B on the holder or a tripod, or place it on a firm, flat
surface. Switch on the measuring tool with the automatic
levelling function enabled and select horizontal mode. Al-
low the measuring tool to level in.
A
B
– At a distance of 2.5 m from the measuring tool, mark the
centre of the laser line on both walls (point Ⅰ on wall A and
point Ⅱ on wall B).
English | 15
B
180°
B
1 609 92A 4HJ | (03.06.2020)