  • ESPAÑOL, página 114
Charge current according to battery volta-
ge at OUT 1
under 15.75V
15.75V-17.5V
17.5V-21V
21V-26.25V
26.25V-31.5V
31.5V-35V
35V-39.37V
39.37V-42V
42V-45V
45V-48.46V
48.46V-52,5V
52.5V-57.27V
57.27V-63V
over 63V
Discharge current according to battery vol-
tage at OUT 1
under 2V
2V-4V
4V-5.33V
5.33V-6.4V
6.4V-8V
8V-8.88V
8.88V-10.66V
10.66V-13.33V
13.33V-16V
16V-17.77V
17.77V-20V
20V-22.85V
22.85V-26.66V
26.66V-29.09V
29.09V-32V
32V-35.55V
35.55V-40V
40V-45.71V
45.71V-53.33V
over 53.33V
Output 2 (OUT2)
Cell counts:
1 ... 8 cells NC / NiMH
1 ... 3 cells LiPo (3.7 V)
1 ... 4 cells LiFe (3.3 V)
Charge current: 0.1 ... 2 A
Charge power: 28 W, automatic current
reduction
Function: charge
Trickle charge: 50 mA (NC / NiMH only)
Operating instructions
Power Peak E1

5. Using the charger for the first time

Connect the charger to a 12 V Lead-acid
battery. It is essential to maintain correct
20A
polarity (red = positive / black = negative).
18A
15A
Make sure the battery terminal clips are
12A
making sound contact.
10A
The Start screen appears, showing the Ver-
9A
8A
sion number and the pre-set user name.
7.5A
7A
6.5A
6A
5.5A
5A
4A
10A
40A
Wait for the charger to conclude its self-cali-
30A
25A
bration process (LEDs go out), then press
20A
the Enter button: the display for the OUT 1
18A
output appears on the screen.
15A
12A
10A
5.1
9A
Connect the battery to the sockets for the
8A
OUT 1 output, maintaining correct polarity
7A
6A
(red = positive / black = negative).
5,5A
If you are using a charge lead adapter ter-
5A
minating in banana plugs, connect the
4.5A
4A
banana plugs to the charger first, and only
3.5A
then connect the battery, as this prevents
3A
2A
the possibility of shorting the battery if the
banana plugs should touch. Reverse the
sequence when disconnecting the battery.
Important: if the charge parameters are
set incorrectly, the battery could be perma-
nently damaged, and even burst into fla-
mes or explode. For this reason: never
start the charge process until you are sure
that you have set the appropriate charge
parameters.
7

Connecting the battery

Order No.
8471
Tabla de contenido
loading

Este manual también es adecuado para:

8471

Tabla de contenido