Cable specifications
Cables must be designed for the intended ambient
temperature.
Cores
Covering
Outer diameter for cable
gland (PointGard 2200, PIR
7x00)
Core cross-section
Length, dependent on sen-
sor and transmitter or control
unit
1) Does not apply to PIR 7x00 sensors. 5-core field wiring must be used
for PIR 7x00 sensors.
Field wiring 3-core or 5-core
Transmitter
Polytron 57x0 / 87x0 IR
Polytron 5310 / 8310 IR
Polytron 5200 / 8200 CAT x
PointGard 2200 CAT
Assembly instructions
|
Junction Box Ex d
1)
3
or 5, braid
≥ 80 %
6-12 mm / 0.2 In - 0.47 In
0.2 mm² - 2.5 mm² /
AWG 24 - 14
Max. 30 m /100 feet
(DD/DQ sensor with Polytron
and PointGard 2200)
Field wiring
3-core
5-core
not possible
x
x
x
x
x
x
|