Ventilation; Operation; Warning - Pinnacle PROTEMP SilentDrive PT-150T-SDR Manual Del Usuario E Instrucciones De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

- Risk of indoor air pollution and Carbon Monoxide Poisoning. Not For Indoor Use. Indoor use permitted only
for the temporary heating of buildings under construction, alteration or repair.
- Refer to Safety Information on page 3 for information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated space of at least three square feet (2,800 sq. cm) for each
100,00 Btu/Hr. (29 kW) of heater output. Provide a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
150T-SDR
5.3 ft.²
3760 cm²
Fueling The Heater:
Kerosene (K-1)
For optimal performance of this heater, it is strongly sug-
gested that K-1 kerosene be used. K-1 kerosene has been
refined to virtually eliminate contaminants, such as sulfur,
which can cause a rotten egg odor during the operation of
the heater. Using diesel fuel can cause excess soot produc-
tion. Do not use Bio-Diesel as this fuel will damage your
heater's seals and filter.
- CSA certified for use with K-1 kerosene,
no. 1 diesel, Jet A Fuel, no. 1 fuel oil.
DO NOT use any fuel that is not approved above.
- NEVER use fuel such as, benzene, alcohol, white gas, camp stove
fuel, paint thinners, farm diesel, or other oil compounds in this
heater. THESE ARE VOLATILE FUELS THAT CAN CAUSE A FIRE
OR EXPLOSION.
- NEVER store kerosene in the living space. Kerosene should be
stored in a well ventilated area outside the living area.
- NEVER store kerosene in direct sunlight or near a source of
heat.
- NEVER use kerosene that has been stored from one season to
the next. Kerosene deteriorates over time. OLD KEROSENE
WILL NOT BURN PROPERLY IN THIS HEATER.
NOTE: Kerosene should only be stored in a blue container that is
clearly marked "Kerosene." Never store kerosene in a red con-
tainer. Red is associated with gasoline.
© 2019 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
®

VENTILATION

220T-SDR
6.5 ft.²
5990 cm²

OPERATION

OR WHILE CONNECTED TO A POWER SOURCE
DANGER
DANGER
HOT OR OPERATING. FIRE OR EXPLOSION COULD
RESULT.

WARNING

CAUTION
THE TANK OUTDOORS. BE SURE THAT THE HEAT-
ER IS ON LEVEL GROUND WHEN FUELING, AND
NEVER OVERFILL THE TANK.
6
Silent Drive Forced Air Heater User's Manual
CARBON MONOXIDE
POISONING MAY LEAD
TO DEATH!
NEVER REFUEL THIS
HEATER WHILE IT IS
DO NOT USE GASO-
LINE OR CRANKCASE
DRAININGS.
NEVER FILL THE
FUEL TANK IN-
DOORS. ALWAYS FILL