Display Controller Operation; Turn On/Off The Heat Pump - WarmPool SILENP-03 Manual De Instrucciones

Mini bomba de calor para piscinas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5. Display controller operation

5.1 The interface of LED wire controller
* When the heat pump is running or standby, the display shows the water inlet
temperature.
* When the heat pump is Power-on, the display shows 'OFF' * Red LEDwill light on when
you turn on the machine.

5.2 Turn on/off the heat pump

Press
to turn on the heat pump, the LED display shows the water setting temperature for 5s, then show
water inlet temperature.
press
again to turn off the heat pump.
NOTE: There is 3 min of time delay protection for the compressor.
5.3 Set the desired water temperature
or
Press
directly to adjust the desired water temperature (parameter d, range:.15—40℃), the data
will be saved in 3 seconds.
Or you can adjust the Parameter d to set your desired water temperature.
NOTE: the heat pump can run only if the water circle/filtration system is running.
5.4 Parameter checking& adjusting
Hold
button for 5 seconds, it will enter the parameter checking, Press
parameters.
or
to check the below