Service, Maintenance And Repairs; Installation - PLYMOVENT FUA-1300 Instrucciones Para El Uso

Ventilador de aspiración
Ocultar thumbs Ver también para FUA-1300:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Modifications
Modification of (parts of) the product is not allowed.

Installation

- The installation of this product is exclusively reserved to
authorised, well-trained and qualified engineers.
- Inspect the product and check it for damage. Verify the
functioning of the safety features.
- Electric connection is to be executed in accordance with local
requirements. Ensure compliance with the EMC regulatory
arrangements.
- During installation, always use Personal Protective
Equipment (PPE) to avoid injury. This also applies to persons
who enter the work area during installation.
- Never install the product in front of entrances and exits
which must be used for emergency services.
- Mind any gas and water pipes and electric cables.
- Make sure that the workshop, in the vicinity of the product,
contains sufficient approved fire extinguishers.
Use
WARNING
Fire hazard! Never use the product for:
- extracting flammable, glowing or burning particles
or solids or liquids
- extracting of aggressive fumes (such as
hydrochloric acid) or sharp particles
- sucking cigarettes, cigars, oiled tissues, and other
burning particles, objects, and acids
WARNING!
Never use the product for:
- aluminium laser cutting
- paint mist
- extraction of hot gases (more than 80°C/176°F
continuously)
- grinding aluminium and magnesium
- flame spraying
- extraction of cement, saw dust, wood dust etc.
- sucking cigarettes, cigars, oiled tissues and other
burning particles, objects and acids
- explosive environments or explosive substances/
- gases
Note: this list is not all-embracing.
- Check the working environment. Do not allow unauthorised
persons to enter the working environment.
- Protect the product against water and humidity.
- Make sure the room is always sufficiently ventilated; this
applies especially to confined spaces.
- Use common sense. Stay alert and keep your attention to
your work. Do not use the product when you are under the
influence of drugs, alcohol or medicine.

Service, maintenance and repairs

- During service, maintenance and repair jobs, always use
Personal Protective Equipment (PPE) to avoid injury. This
also applies to persons who enter the work area during
installation.
- Always use tools, materials, lubricants and service
techniques which have been approved by the manufacturer.
Never use worn tools and do not leave any tools in or on the
product.
- Safety features which have been removed for service,
maintenance or repairs, must be put back immediately after
finishing these jobs and it must be checked that they still
function properly.
0000100435/060614/A FUA-1300/1800/2100/3000/4700 (50Hz)
4
INSTALLATION
4.1
Unpacking
Check that the product is complete. The package should
contain:
- extraction fan incl. inlet grid 3 mm (0.12 in.)
- connection flange with grid
Options and accessories
The MB-FUA/S1-2 should contain:
- mounting bracket
- connection flange with grid (S1 only)
- tube clamps (4)
- hardware
The MB-FUA/C1-2 should contain:
- mounting bracket
- connection flange (C1 only)
- hardware
The OL (outlet transition) should contain:
- square to round outlet transition
The SC (soft connection) should contain:
- soft connection with 2 hose clamps
If parts are missing or damaged, contact your supplier.
4.2
Installation
4.2.1
Tools and requirements
The following tools and requirements are needed to install the
product:
- wrench 10
- wrench 13
- wrench 17
- screwdriver
4.2.2
Installing the fan on an MB-FUA-S1/S2
For use as a standalone or for mounting on the wall, ceiling or
a platform. The motor can be installed resting on the stand.
The motor of the FUA-1300/1800/2100 can also be installed
upside down (hanging from the stand, not shown).
To install the fan on an MB-FUA-S1/S2 stand, proceed as
follows:
Fig. 4.1
• Install the stand in the desired place.
• Attach the tube clamps (B) as desired, if applicable.
• Tighten the tube clamps with suitable hardware (not
supplied; material depending on wall, floor or ceiling type).
• Position the fan on the stand as desired.
• Tighten the bolts (A).
EN - 5
Tabla de contenido
loading

Este manual también es adecuado para:

Fua-1800Fua-2100Fua-3000Fua-4700

Tabla de contenido