Gessi 32948 Manual De Instrucciones página 13

IMPIANTO IDRAULICO - PLUMBING SYSTEM - INSTALLATION HYDRAULIQUE - HYDRAULISCHE ANLAGE -
INSTALACIÓN HIDRÁULICA - ГИДРАВЛИЧЕСКАЯ СИСТЕМА - ΥΔΡΑΥΛΙΚΟ ΣΥΣΤΗΜΑ -
Technical data for the plumbing system:
- Minimum working pressure: 2 bar (200 kPa)
- Working pressure: recommended operating field 3÷4 bar (300÷400 kPa)
- Maximum working pressure: 5 bar (500 kPa) (Install a pressure reducer for higher hydraulic pressures)
- Maximum working temperature: 65°c
- Floor waste required with capacity ≥ 60 l/min.
- 10 kg empty weight of the complete head shower (with water about 11,1 kg)
Feeding pipes for the shower system [A1 - A2 - A3]: minimum internal diameter 12 mm
Static
pressure
2 bar (200 kPa)
3 bar (300 kPa)
4 bar (400 kPa)
5 bar (500 kPa)
( 1 ) Minimum delivery from head shower for the correct working "Rain": 13 l/min [ B1 ].
( 2 ) Minimum delivery from head shower for the correct working "Cascade": 11 l/min [ B2 ].
( 3 ) Minimum pressure for the correct working "Water spray": > 2 bar (200 kPa).
Static
pressure
2 bar (200 kPa)
3 bar (300 kPa)
4 bar (400 kPa)
5 bar (500 kPa)
(*) For the correct working of the cascade, with working pressures ≥ 3 bar (300 kPa) always install a flow
limiter (16 l/min).
Data for plant dimensioning
for a correct working of the shower system
( 1 )
Rain Function [A1]
[ l/min ]
22
21
20
19
Data for boiler and waste dimensioning
Maximum delivery for the shower system
fed with internal 12 mm Ø pipes
Rain Function [B1]
[ l/min ]
16 [ with limiter ]
16 [ with limiter ]
16 [ with limiter ]
16 [ with limiter ]
13
Minimum required feeding
( 2 )
Cascade Function [A2]
[ l/min ]
17
16
15
14
Cascade Function* [B2]
[ l/min ]
16
16 [ with limiter ]
16 [ with limiter ]
16 [ with limiter ]
水力设备
ING
( 3 )
Water Spray Function [A3]
[ l/min ]
It is not
binding
Water Spray Function [B3]
[ l/min ]
0,8
1
1,2
1,3
loading