10 mm
(0.39 in)
M12
45 Nm - 400 lb-in
A1
A2
M3.5
1 Nm - 7 Ib-in
100-EC1060
100-EA*
!
According to UL 60947-4-1
100-E1060: Use Terminal Lug Kit 100-ETL1060, (3) 1/0 AWG...750 MCM, Cu 75°C only, 57 Nm, 500 lb-in
100-E860: Use Terminal Lug Kit 100-ETL1060, (3) 1/0 AWG...750 MCM, Cu 75°C only, 57Nm, 500lb-in
or Terminal Lug Kit 100-ELT860, (2) 4/0 AWG...500 MCM, Cu 75°C only, 43 Nm, 375lb-in
100-E2050: At 2100A 600V AC, use copper bars each of minimum four busbars per terminal
21/2 inch (width) by 1/4 inch (thickness).
At 1900 A 600V DC, use copper bars each of minimum two busbars per terminal 4 inch
(width) by 1/4 inch (thickness). Three poles connected in series.
100-E860, 100-E1060 and 100-E2050 Enclosure with three latches and with min dimension
79 by 32 by 20 inches should be used
All contactors: *Designed for max 40°C surrounding temperature.
ø 5.0 mm
Pz 2
(0.20 in)
Torx T25
x18
40 lb-in
4.5 Nm
35 lb-in
4 Nm
Torx T25
Flexible
Solid / Stranded core
2 x 1...2.5 mm²
2 x 0.75...2.5 mm²
2 x AWG 18...14
2 x AWG 18...14
°
C
CU 75
x6
Torx T30
100-EA860, 1060, 2050
contacts at the same time.
Lugs
I > 3.5 mm
(0.14 in)
L < 8 mm
(0.31 in)
100-EC1060
x9
100-EA860, 1060, 2050
contacts at the same time.
6 mm
(0.24 in)
M8
195 lb-in
22 Nm
3/6
100 mm
(3.94 in)
100-EC1060
x6