ASSEMBLE AND ADJUSTMENTS
MOUNTING AND ADJUST THE RIVING KNIFE
The supplied riving knife must always be used.
The riving knife has to be adjusted in such a way that over its
entire length the gap between saw blade and riving knife does
not exceed min.3 mm and max.8 mm (Fig 12).
Fig. 12
TO ADJUST THE RIVING KNIFE:
1. Disconnect the saw from the power source.
2. Move the blade tilt to 0º (blade 90º to table)
and raise the main blade all the way up.
3. Check both sides of the blade with a straight edge
touching the teeth as shown in Figure 15:
---If the straightedge touches the riving knife
evenly on both sides, go to step 4.
---if the straightedge only touches the riving
knife on one side, go to step 5.
Fig. 15 (checking riving
knife alignment)
Blade
Blade
washer
Arbor
shaft
Blade nut
Fig. 11
3 -8 mm
4. Place a machinist's square flat on the table and slides
it against the riving knife as shown in Figure 16:
Fig. 16 (checking vertical alignment)
--- If the square lies flat against the riving knife,
the riving knife is correctly adjusted.
--- If there is a gap between the square and
the riving knife, go to Step 6.
5. Loosen the riving knife center bolt and remove
the riving knife.
6. Use the set screws shown in Figure 17 to adjust
the riving knife bracket and re-install the riving knife.
Fig.17 (set screw for adjusting riving knife)
7. Repeat step 3-7 until the riving knife is centered
on the blade and aligned at 90º to the table.
8. Position the riving knife about 3mm or 1/8" away
from the nearest carbide tooth on the main blade.
9. Lock the riving knife on the safety and appropriate
position.